Eagle: Eagle shows prefix ‘-‘ in front of alarms
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-16634751541>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 46.3 and later
Tekelec
Goal
How to clear the prefix ‘-‘ in front of alarms in Eagle
> rept-stat-alm
Eagle 17-10-13 14:06:39 GMT EAGLE 46.3.1.0.0-68.30.1
rept-stat-alm
Command entered at terminal #20.
;
Command Accepted - Processing
Eagle 17-10-13 14:06:39 GMT EAGLE 46.3.1.0.0-68.30.1
ALARM TRANSFER= RMC
ALARM MODE CRIT= SILENT MAJR= SILENT MINR= AUDIBLE
ALARM FRAME 1 CRIT= 0 MAJR= 0 MINR= -1
ALARM FRAME 2 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 3 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 4 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 5 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 6 CRIT= 0 MAJR= 0 MINR= 0
PERM. INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
TEMP. INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
TIMED INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
ACTIVE ALARMS CRIT= 0 MAJR= 0 MINR= -1
TOTAL ALARMS CRIT= 0 MAJR= 0 MINR= -1
Command Completed.
;
Solution
To clear the prefix ‘-‘ in front of alarms in Eagle , It is recommended to perform a MASP switchover
Procedure to perform MASP Switchover -:
Step1 - Identify Active MASP using command rept-stat-db
Step 2 - Execute init-card:loc=<Active MASP>
Step 3 - Verify rept-stat-db again to identify the newly Active MASP
After MASP switchover again execute the rept-stat-alm command to verify that ‘-‘ prefix is cleared.
> rept-stat-alm
Eagle 17-10-13 14:06:39 GMT EAGLE 46.3.1.0.0-68.30.1
rept-stat-alm
Command entered at terminal #20.
;
Command Accepted - Processing
Eagle 17-10-13 14:06:39 GMT EAGLE 46.3.1.0.0-68.30.1
ALARM TRANSFER= RMC
ALARM MODE CRIT= SILENT MAJR= SILENT MINR= AUDIBLE
ALARM FRAME 1 CRIT= 0 MAJR= 0 MINR= 1
ALARM FRAME 2 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 3 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 4 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 5 CRIT= 0 MAJR= 0 MINR= 0
ALARM FRAME 6 CRIT= 0 MAJR= 0 MINR= 0
PERM. INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
TEMP. INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
TIMED INH. ALARMS CRIT= 0 MAJR= 0 MINR= 0
ACTIVE ALARMS CRIT= 0 MAJR= 0 MINR= 1
TOTAL ALARMS CRIT= 0 MAJR= 0 MINR= 1
Command Completed.