Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2375329.1
Update Date:2018-03-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  2375329.1 :   EAGLE : M2PA/M3UA Latency For International Sigtran Connection  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-16823191011>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 44.x and later
Tekelec

Goal

Is There an Acceptable M2PA/M3UA Latency For International SIGTRAN Connection.

Solution

We have no parameters to define or configure network latency as it varies with customer networks. Based on experiences in the field, Oracle has deviated from some RFC-recommended timer settings, especially those related to re-transmission, to better accommodate signaling networks.
The default mode for the re-transmission timer (RMODE) is linear, whereas the RFC-recommended timer setting is exponential.

Oracle makes both settings available through configuring an association to use either the Linear (LIN) or the exponential (RFC) method. For more information about both modes and the timer settings, see SCTP Timers.

So, Based on network latency, our parameters can be adjusted, Please go through the below link from Page 70 to 75 , It does contain all the information :

https://docs.oracle.com/cd/E76234_01/docs.463/E72204_rev_1.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.