Goal
Solution
References


Created from <SR 3-17020631433>

Applies to:

Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Ethernet interface on the Oracle Switch ES1-24 is stuck or shows not connected due to repeated link resets.
Oracle Switch ES1-24 SEFOS Environment is hung and needs a reboot when ILOM is accessible.

Goal

How to Reboot Oracle Switch ES1-24?

Solution

CAUTION: Before performing any reboot or power-cycle of Oracle Switch ES1-24 it is advised to take a back up of the switch configuration. Refer MOS Note: How to backup an Oracle 10Gb Ethernet Switch prior to replacement (Doc ID 1572791.1)


Below solution is applicable in case user needs to either reboot/start/stop the SEFOS Environment and/or Oracle ILOM service processor (SP) as a part of a fault diagnosis or a change management.

From Oracle Switch ES1-24 ILOM:

How do I restart/reboot SEFOS?

-> show /SP/clock/ uptime (to validate the Switch Up time)

-> stop /SYS/sefos
Are you sure you want to stop /SYS/sefos (y/n)? y
stop: SEFOS stopped successfully.

-> start /SYS/sefos
Are you sure you want to start /SYS/sefos (y/n)? y
start: Please wait while sefos comes up, this can take anywhere from 30 seconds to 2 minutes depending on the configuration
..................
start: SEFOS started successfully.

-> show /SP/clock/ uptime

 

How do I reset the SP?

-> reset /SP
Are you sure you want to reset /SP (y/n)? y
Performing reset on /SP

Broadcast message from root (Day Month Date Time Year):

The system is going down for reboot NOW!

Note: Above command resets both ILOM and SP.

 

How do I reset the SYS?

-> reset /SYS
Are you sure you want to reset /SYS (y/n)? y
Performing hard reset on /SYS

Broadcast message from root (Sat Mar 10 06:37:23 2018):

The system is going down for reboot NOW!

Note: Performing hard reset on /SYS will take some time for the /SYS to establish network connection back. (2-3mins)

 

 

 

 