Goal

Performing spid migration with iConectiv. We stopped npaagent, eagle agent and sup, ran the massupdate with the SMURF file generated by iConnectiv.

massupdate -n Region SMURF_file

rw-r----- 1 lsmsadm root 42 Feb 26 15:11 SIC-SMURF-LRN.T220.T830.25-02-2018060201
-rw-r----- 1 lsmsadm root 34 Feb 26 15:11 SIC-SMURF-NPANXX.T220.T830.25-02-2018060201
-rw-r----- 1 lsmsadm root 36 Feb 26 15:11 SIC-SMURF-NPANXXX.T220.T830.25-02-2018060201


After runing the massupdate, and starting npacagents, eagle agents and sup, the data (TN, LRN, ect ) in LSMS changed with the new SPID which is what we expected, but ELAP and STP still show the old SPID.

How can this update ELAP and STP.


Solution


The SPID doesn't get audited, but other values are.

Per Chapter 5 in the guide below. Need to load servdi/bulkload to update ELAP and Eagle with the new SPID (but not necessary) as the information you need for routing are correct.