![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2369960.1 : The SPID Updates For iConectiv Spid Migration are Updated on LSMS only but not Pushed to ELAP and Eagle
In this Document
Created from <SR 3-16962215451> Applies to:Oracle Communications EAGLE (Software) - Version LSMS 13.3 and laterInformation in this document applies to any platform. GoalPerforming spid migration with iConectiv. We stopped npaagent, eagle agent and sup, ran the massupdate with the SMURF file generated by iConnectiv. massupdate -n Region SMURF_file How can this update ELAP and STP. Solution
Per Chapter 5 in the guide below. Need to load servdi/bulkload to update ELAP and Eagle with the new SPID (but not necessary) as the information you need for routing are correct. LNP Database Synchronization User's Guide Attachments This solution has no attachment |
||||||||||||||
|