Goal

 How to Reset iLO for any HP Server

Solution

 iLO for any HP Server can be reset by either Command Line Interface (CLI) or Graphical User Interface (GUI).

How to Reset via CLI :

Connect to the iLO of Server using command line and run : reset map1

</>hpiLO-> reset map1

status=0
status_tag=COMMAND COMPLETED
Mon Feb 26 09:19:53 2018

Resetting iLO.

CLI session stopped

It will reset the iLO, you can verify the same from iLO GUI , You will be seeing the below message under :

iLO GUI => Information => iLO Event Log

How to Reset via GUI :

Login to iLO GUI of Server

Go to Information => Diagnostics

Reset iLO

 
It will reset the iLO, you can verify the same from iLO GUI, You will be seeing the below message under :

iLO GUI => Information => iLO Event Log