Solution Type Technical Instruction Sure Solution 2365743.1 : Diameter Signaling Router (DSR) : How to Reset iLO for HP Server
In this Document
Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 to DSR 8.2.0 [Release DSR 5.0 to DSR 8.0]Tekelec GoalHow to Reset iLO for any HP Server SolutioniLO for any HP Server can be reset by either Command Line Interface (CLI) or Graphical User Interface (GUI). How to Reset via CLI : Connect to the iLO of Server using command line and run : reset map1 </>hpiLO-> reset map1 status=0 Resetting iLO. CLI session stopped It will reset the iLO, you can verify the same from iLO GUI , You will be seeing the below message under : iLO GUI => Information => iLO Event Log How to Reset via GUI : Login to iLO GUI of Server Go to Information => Diagnostics Reset iLO iLO GUI => Information => iLO Event Log Attachments This solution has no attachment |
||||||||||||||
|