![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2365697.1 : How To Clear Alarm Event 22061 ETG Monitoring Stopped With Error Info No DA-MP Leader
In this Document
Created from <SR 3-16565856201> Applies to:BNS Platform Hardware - Version DSR 7.3.0 and laterTekelec GoalFollowing Alarm appeared in DSR system :- SolutionNew MPs had been added to DSR but still no connections were created with new MPs (MP-3 and MP-4). Somehow MP-3 was showing as MP leader despite of no Diameter connections. Advised to restart MP-3 and MP-4 using Status&Manage SOAM GUI. When they were stopped, MP-1 become leader(having diameter connections) which cleared the alarm. Verifying MP leader role in active SOAM:- 1. Login to SOAM GUI using VIP. Any MP with active diameter connections should be MP leader.