Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2360435.1
Update Date:2018-03-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  2360435.1 :   Eagle: No Display for the Secondary Path However the Configuration Shows Multi-homed  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-16564799201>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 46.0 and later
Tekelec

Goal

Below we can see that the association is multi-homed
==================================================================================================

rtrv-assoc:aname=<assoc name>

    tklcstp 18-01-04 13:44:09 tz  EAGLE 46.x.x.x.x
    rtrv-assoc:aname=<assoc name>
    Command entered at terminal #22.
;

Command Accepted - Processing
    tklcstp 18-01-04 13:44:09 tz EAGLE 46.x.x.x.x

    ANAME <assoc name>
          LOC      2212          IPLNK PORT A,B         LINK     B4
          ADAPTER  M3UA          VER        M3UA RFC
          LHOST    LocalHost.1.1.1.1
          ALHOST   ALocalHost2.2.2.2
          RHOST    RemoteHost3.3.3.3
          ARHOST   ARemoteHost4.4.4.4 <============= multi homed association
          LPORT    2905          RPORT      4005
          ISTRMS   2             OSTRMS     2           BUFSIZE  200
          RMODE    LIN           RMIN       300         RMAX     500
          RTIMES   10            CWMIN      3000        UAPS     10
          OPEN     YES           ALW        NO          RTXTHR   65535
          RHOSTVAL RELAXED       HBTIMER    1000

          LSN
          LSNName

    IP Appl Sock/Assoc ( 395 of 4000) 10%
    Assoc Buffer Space Used (3200 KB of 6400 KB) on LOC = 2212

;
Command Executed

************************************************

Below pass command output shows no display for secondary IP

pass:loc=2212:cmd="sctp -a <assoc name>"

    tklcstp 18-01-04 13:44:09 tz EAGLE 46.x.x.x.x


    pass:loc=2212:cmd="sctp -a <assoc name>"
    Command entered at terminal #22.
;

    tklcstp 18-01-04 13:45:55 IST  EAGLE 46.3.0.0.1-68.27.0
    PASS: Command sent to card
;
Command Accepted - Processing
    tklcstp 18-01-04 13:44:09 tz EAGLE 46.x.x.x.x

    SCTP command complete

;
Command Executed


    tklcstp 18-01-04 13:44:09 tz EAGLE 46.x.x.x.x


    Aname             Local              Local   Remote             Remote
                      Address            Port    Address            Port
    <assoc name>      1.1.1.1            2905    3.3.3.3            4005
                      2.2.2.2

 

Solution


The lack of display of the Secondary in the pass command means the secondary IP has not been inserted in the INIT packet sent by the far end.

In order to verify this we can do the following:

Activate trace (from PIC or port re-mirroring) and then reset the link towards the far-end to restart the initialization process and capture the trace. In this way we can capture the INIT message and confirm.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.