Solution Type  Technical Instruction Sure

Solution  2358367.1 :   Integrated Diameter Intelligence Hub Mediation (IDIH-MED) Server Does Not Boot Up To Normal State (DbUp state)  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution
References


Created from <SR 3-16779314091>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 8.1.1 and later
Information in this document applies to any platform.

Goal

IDIH-MED server does not boot up to normal state(DbUp state)
 

Solution

IDIH 8.2...

To correct the issue please follow below steps :
1. Login to mediation server as "admusr" and change the user as tekelec "sudo su - tekelec".
2. Manually restart the mediation process by running this command "prod.stop; prod.start".
 

References