Asset ID: |
1-71-2357764.1 |
Update Date: | 2018-02-12 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2357764.1
:
RTDB Is Inconsistant
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-16625356171>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 16.2 and later
Information in this document applies to any platform.
Goal
After upgrade from EPAP 16.0 to EPAP 16.2, got RTDB is Inconsistent for both EPAP in Standby PDBA
Solution
Perform the Restore RTDB using PDB for EPAP B at Site STP01
RTDB on EPAP B is COHERENT now..
We will perform Reload RTDB on EPAP A from mate i.e. EPAP B now...
EPAP A has been reloaded from PDB
EPAP B has been reloaded from EPAP A
RTDBs on A and B are coherent.
Attachments