![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2357328.1 : OCEEMS MIBs do not Compile if the TEKELEC-TOPLEVEL-REG file supplied with DSR or PIC Products is Used
In this Document
Created from <SR 3-16406815571> Applies to:Oracle Communications EAGLE (Software) - Version E5-MS 46.5 and laterTekelec GoalWhile implementing the MIB files to Network Management System (NMS) by using TEKELEC-TOPLEVEL-REG with version 201412170000Z that is delivered with one of the MIB packages for either DSR or PIC, the EMS MIBs do not compile. SolutionTEKELEC-TOPLEVEL-REG provided with PIC and DSR is different from the one provided with EAGLE/OCEEMS softwares in the software download centre. tekelecEagleEMS OBJECT IDENTIFIER ::= { tekelecSwitchingGroup 24 }
TEKELEC-TOPLEVEL-REG with version 201412170000Z contains following entry for EMS: tekelecEAGLEEMS OBJECT IDENTIFIER ::= { tekelecSwitchingGroup 24 }.
As the Oracle Communications Eagle Element Management System (OCEEMS) specific Management Information Database (MIB) files are using the tekelecEagleEMS obviously the MIBs are orphaned.
OCEEMS CoE Collab: 3-16420005031 Who suggested going to DSR field help Field Support RT help ticket #17875 Who suggested going to Platform support JIRA Ticket for platform support: CPE-1005Platform team confirmed that the relevant MIBs will be updated in next OCEEMS release documentation.
Attachments This solution has no attachment |
||||||||||||||
|