Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2356086.1
Update Date:2018-03-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  2356086.1 :   Health Check Warnings on BDA Servers on BDA Versions 4.9 or Lower with 8 TB drives - model HGST H7280B520SUN8.0T Can Be Ignored  


Related Items
  • Big Data Appliance Hardware
  •  
  • Big Data Appliance Integrated Software
  •  
Related Categories
  • PLA-Support>Eng Systems>BDA>Big Data Appliance>DB: BDA_EST
  •  




In this Document
Goal
Solution


Applies to:

Big Data Appliance Hardware - Version All Versions and later
Big Data Appliance Integrated Software - Version 4.0 and later
Linux x86-64

Goal

BDA v4.10.0 and higher versions have support added for the new replacement 8 TB drives - model HGST H7280B520SUN8.0T.

For BDA clusters running older versions i.e. running BDA V4.9 or lower, there will be health check warnings which can be ignored.

The following conditions must exist for the health check warnings to occur:

  1. The system must have 8TB high capacity disk drives with make/model HGST H7280B520SUN8.0T.
  2. The BDA servers must be running BDA V4.9 or lower.

 

Solution

On BDA V4.9 or lower, any servers with a replacement 8TB high capacity disk drive with make/model HGST H7280A520SUN8.0T will raise health check warnings.  The warnings look like:

...
ERROR: Wrong disk 0 model : HGST H7280B520SUN8.0
INFO: Expected disk 0 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 1 model : HGST H7280B520SUN8.0
INFO: Expected disk 1 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 2 model : HGST H7280B520SUN8.0
INFO: Expected disk 2 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 3 model : HGST H7280B520SUN8.0
INFO: Expected disk 3 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 4 model : HGST H7280B520SUN8.0
INFO: Expected disk 4 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 5 model : HGST H7280B520SUN8.0
INFO: Expected disk 5 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 6 model : HGST H7280B520SUN8.0
INFO: Expected disk 6 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 7 model : HGST H7280B520SUN8.0
INFO: Expected disk 7 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 8 model : HGST H7280B520SUN8.0
INFO: Expected disk 8 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 9 model : HGST H7280B520SUN8.0
INFO: Expected disk 9 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 10 model : HGST H7280B520SUN8.0
INFO: Expected disk 10 model : HGST H7280A520SUN8.0 .
ERROR: Wrong disk 11 model : HGST H7280B520SUN8.0
INFO: Expected disk 11 model : HGST H7280A520SUN8.0 .
...
ERROR: Big Data Appliance failed hardware validation checks

 

To resolve:

1. Upgrade to BDA V4.10.0 or higher which have support added for the new replacement 8 TB drives - model HGST H7280B520SUN8.0T.

2. If upgrade is not possible on BDA V4.9 or lower versions ignore the related health check warnings.


Attachments