Solution Type Technical Instruction Sure Solution 2353767.1 : VSM4 VSM5 - How to IML a VTSS from the LOP or DOP
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases]Sun StorageTek VSM5 System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalIML the VTSS IML the VSM4 or VSM5 SolutionStep by step procedure to IML the VSM4 or VSM5 Customer engagement Field Engineer Engagement Customer engagement
The below information can be found in the D02.21.00.00 Release notes. Notes Ensure no FRUs are fenced before proceeding.
LOP:
1) Navigate to the CSE main menu (PS02). 2) At the CSE main menu (PS02), depress F10 - FILE UTIL. 3) At the file utility menu (FU01), depress F5 - SLCT SSYS. 4) At the select software release level screen (FU11), using the F7 - CURS DOWN or the F6 - CURS UP highlight the current software release level (SRL) that is to be IML'ed. 5) With the required SRL highlighted, depress F10 - IML SRL. 6) At the IML Software Revision Level Menu (FU28), depress F8 DISR LOAD 7) Confirm the selection; depress F9 -YES 8) Upon completion of the IML, 9) IMPORTANT!!!! • After a Cold IML or NDCL with arrays formed, wait until this message is observed in hic_stat.dia before performing ANY DOP/LOP maintenance actions. "IT IS SAFE TO PERFORM MAINTENANCE ACTIONS" • Failure to do so could result in maintenance ACTION failures or loss of configuration data. 10)NOTE: if no arrays are yet formed, wait for message "CMS: Remaining Freezer Complete' before maintenance actions. 11) Confirm no diagnostic failures before returning the subsystem to the customer
DOP:
1) From 'Software Release Level' screen, select the current software release level (SRL) to be IML'ed. 2) Select IML 3) Upon completion of the IML, 4) IMPORTANT!!!! • After a Cold IML or NDCL with arrays formed, wait until this message is observed in hic_stat.dia before performing ANY DOP/LOP maintenance actions. "IT IS SAFE TO PERFORM MAINTENANCE ACTIONS" • Failure to do so could result in maintenance ACTION failures or loss of configuration data. • note: if no arrays are yet formed, wait for message "CMS: Remaining Freezer Complete' before maintenance actions.” 5) Confirm no diagnostic failures before returning the subsystem to the customer.
Attachments This solution has no attachment |
||||||||||||||
|