Infiniband Patch Fails with 'Error: Insufficient Disk Space/memory'
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
In this Document
Created from <SR 3-16715293401>
Applies to:
Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
On : Infiniband Switch on Exadata Database Machine
Infiniband patch fails with:
Error: Insufficient disk space/memory.
Attempting to patch infiniband from version 2.2.5-3 to 2.2.7-1 using the firmware patch delivered with Exadata storage cell bundle patch 18.1.3.0.0.171219.2.
Patch fails with
----- InfiniBand switch update process ended 2018-01-23 14:41:34 -0600 -----
2018-01-23 14:41:34 -0600 :FAILED : For details, check the following files in the /EXAVMIMAGES/stage/cell/patch_18.1.3.0.0.171219.2:
2018-01-23 14:41:34 -0600 1 of 1 :FAILED : - upgradeIBSwitch.log
2018-01-23 14:41:34 -0600 1 of 1 :FAILED : - patchmgr.stdout
2018-01-23 14:41:34 -0600 1 of 1 :FAILED : - patchmgr.stderr
2018-01-23 14:41:34 -0600 1 of 1 :FAILED : - patchmgr.log
2018-01-23 14:41:34 -0600 1 of 1 :FAILED : DONE: Upgrade InfiniBand switch(es) to 2.2.7-1.
- From ----- START STDOUT -----
Oracle(R) Integrated Lights Out Manager
Version 2.2.5-3 ILOM 3.2.6 r116001
Copyright (c) 2017, Oracle and/or its affiliates. All rights reserved.
Warning: HTTPS certificate is set to factory default.
Hostname: jmcxasw-ibb01
-> load -o verbose -script -source scp://root@jmcxvdbadm01.oracle.com//EXAVMIMAGES/stage/cell/patch_18.1.3.0.0.171219.2/sundcs_36p_repository_2.2.7_1.pkg
Error: Insufficient disk space/memory. Firmware update requires minimum of
150 MB space in /tmp directory
1 MB space in /config directory
1 MB space in /var/log directory
150 MB of free memory
Please check the disk space/memory available and free it as per
requirement.
Solution
Rebooting the Infiniband Switch cleared the issue, allowing to proceed with the patching.
Reference:
How to clear for memory spaces when memory of an IB switch (NM2-36P and NM2-GW) becomes full or almost full. (Doc ID 1987078.1)