Asset ID: |
1-71-2347078.1 |
Update Date: | 2018-01-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2347078.1
:
Load Sharing In MRNSET Not Working For G-Port SRI Query For Prepaid .
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-16593901681>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 45.0 and later
Information in this document applies to any platform.
Goal
SCCP load sharing (MRNSET and MAPSET) not working for G-Port for prepaid and G-port features for routing SRI_ACK
Solution
Routing an SRI Ack message to a network domain different from the network domain from which query was received is not supported by G-Port. Routing failures or unexpected routing of SRI Ack messages may result.
Gport for prepaid and GPort features does not support SCCP load sharing (MRNSET and MAPSET) for routing SRI_ACK.