Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2347078.1
Update Date:2018-01-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  2347078.1 :   Load Sharing In MRNSET Not Working For G-Port SRI Query For Prepaid .  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-16593901681>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 45.0 and later
Information in this document applies to any platform.

Goal

SCCP load sharing (MRNSET and MAPSET) not working for G-Port for prepaid and G-port features for routing SRI_ACK
 

Solution

Routing an SRI Ack message to a network domain different from the network domain from which query was received is not supported by G-Port. Routing failures or unexpected routing of SRI Ack messages may result.

Gport for prepaid and GPort features does not support SCCP load sharing (MRNSET and MAPSET) for routing SRI_ACK.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback