![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2346930.1 : DSR NOAM Diameter -> Maintenance -> Connections GUI Shows 2 Of 4 MPs In Unknown State
In this Document
Created from <SR 3-16471702741> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and laterInformation in this document applies to any platform. GoalMP-1A and MP-1B of DSR both show zero connections assigned after DSR 7.0.1 upgrade. All Initiator Connections were configured by customer to one of those 2 MPs and those connections now show an "Unk" (unknown) value for the assigned MP. Recent Changes:
SolutionBug 21356236 is being observed on the 2 MP's as the hostname is 20 characters (AAA-BBBBB-DRA-MP-1A and AAA-BBBBB-DRA-MP-1B). The connections that are being shown in Unknown state are hosted on these 2 MPs. The workaround would be to remove these 2 MP’s from the server group and delete the servers and then re-IPM them and configure them with a smaller hostnames (up to 19 characters). This bug is fixed in DSR 7.1 release onwards. References<BUG:21356236> - HOSTNAME FIELD DOES NOT SUPPORT 20 CHAR LENGTH AS ADVERTIZEDAttachments This solution has no attachment |
||||||||||||||||
|