How to Replace an Oracle Server X7-2 CPU & Heatsink
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: This is a FRU
Applies to:
Oracle Server X7-2 - Version All Versions to All Versions [Release All Releases]
x86_64
Goal
How to Replace an Oracle Server X7-2 CPU & Heatsink.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Oracle Server X7-2 Training
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 3
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: An Oracle Server X7-2 CPU & Heatsink needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Caution - Ensure that all power is removed from the server before removing or installing a processor. You must disconnect the power cables from the system before performing these procedures.
X7-2 CPU Removal and Replacement Procedure:
https://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc
If the system is still up and functioning, the customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an antistatic wrist strap to your wrist, and then to a grounded area on the rack.
- Remove the server top cover.
- Lift the air baffles up and out of the server and set them aside.
Note - On single-processor systems, processor socket 1 (P1) is shipped without a heatsink and processor filler cover. To protect the delicate processor socket pins, do not remove the processor cover that was installed on the motherboard.
2. Identify the location of the faulty processor by pressing the Fault Remind button on the motherboard. The processor fault LED for the faulty processor lights. The processor fault LEDs are located next to the processors. If the processor fault LED is off, then the processor is operating properly. If the processor fault LED is on (amber), then the processor is faulty and must be replaced.
Note - When you press the Fault Remind button, an LED located next to the Fault Remind button lights green, indicates that there is sufficient voltage in the fault remind circuit to light any fault LEDs that were lit due to a failure. If this LED fails to light when you press the Fault Remind button, it is likely that the capacitor powering the fault remind circuit lost its charge. This can happen if you press the Fault Remind button for a long time with fault LEDs lit, or if power was removed from the server for more than 15 minutes.
3. Using the 12.0 in-lbs Torx T30 driver (part number 7352217), loosen the four captive nuts that secure the processor-heatsink module to the socket: fully loosen nut 4, then 3, then 2, then 1.
4. Lift the processor-heatsink module from the socket. Always hold the processor-heatsink module along the ends of the fins to prevent damage, not the flat sides.
5. Separate the processor from the heatsink:
- Flip over the processor-heatsink module, place it on a flat surface, and locate the thermal interface material (TIM) breaker slot.
- While holding down the processor-heatsink module by the edges, insert a flat blade screwdriver into the TIM breaker slot. The blade of the screwdriver goes into the slot between the heatsink and processor carrier, not between the processor and processor carrier.
- Using a rocking motion, gently pry the corner of the processor carrier away from the heatsink.
- Remove the processor carrier with processor from the heatsink by prying or pinching the plastic latch tabs that attach the processor to the heatsink.
Note - A thin layer of thermal grease separates the heatsink and the processor. This grease acts as an adhesive. Do not allow the thermal grease to contaminate the work space or other components.
Caution - Be careful not to touch the processor socket pins. The processor socket pins are very fragile. A light touch can bend the processor socket pins beyond repair.
6. If you plan on reusing either the heatsink or processor, use an alcohol pad to clean the thermal grease on the underside of the heatsink and on the top of the processor.
Caution - Failure to clean thermal grease from the heatsink could result in the accidental contamination of the processor socket or other components. Also, be careful not to get the grease on your fingers, as this could contaminate components.
Caution - Whenever you remove a processor, replace it with another processor and reinstall the processor heatsink; otherwise, the server might overheat due to improper airflow.
Installing the CPU.
1. Unpack the replacement processor but do not remove it from the packaging tray.
2. Ensure that the replacement processor is identical to the failed processor that was removed.
3. Prepare the new processor for installation:
- Use the syringe supplied with the new or replacement processor to apply 0.3 cc of thermal interface material (TIM) in an "X" pattern to the processor contact area of the heatsink.
- Note - Do not distribute the TIM; the pressure of the heatsink will do so for you when you install the heatsink.
4. Install the new processor:
- Align the pin 1 indicators between the heatsink and processor carrier in the packaging tray, and place the heatsink (thermal side down) onto the processor carrier until it snaps in place and lies flat. Note - The processor carrier has latching posts at each corner: two that insert into heatsink holes and two that attach to the edge of the heatsink.
- Lift the processor-heatsink module out of the packaging tray.
- Align the processor-heatsink module to the processor socket bolster plate on the motherboard, matching the pin 1 location (a triangle indicator).
- Place the processor-heatsink module on the socket on the motherboard. The socket bolster plate has alignment pins that go into holes on the processor-heatsink module to help center the module during installation.
- Ensure that the processor-heatsink module lies evenly on the bolster plate and that the captive screws align with the threaded socket posts.
- Using a 12.0 in-lbs (inch-pounds) torque driver (part number 7352217) with a Torx T30 bit, tighten the processor-heatsink module to the socket. First, fully tighten captive nuts 1 and 2. Then fully tighten nuts 3 and 4. As you tighten nuts 3 and 4, some resistance occurs as the bolster leaf spring rises and comes in contact with the heatsink.
- If a 12.0 in-lbs torque driver is not available, the CPU heatsink can be safely installed with the following guidelines. Using a torx T30 hand tool (not electric), with a simple screwdriver type handle, gently tighten each of the screws until they bottom-out, at which point a sharp increase in resistance will be felt. At that point apply only a modest tightening torque by hand, such as you would apply when turning a door-knob to open a door.
5. Return the Server to operation:
- Install the air baffles.
- Install the server top cover.
- Return the server to the normal rack position.
- Reconnect the power cords to the server power supplies and reconnect the data cables.
- Power on the server.
6. Use Oracle ILOM to clear server processor faults.
a. To show server faults, log in to the server as root using the Oracle ILOM CLI, and type the following command to list all known faults on the system:
-> show /SP/faultmgmt
The servers lists all known faults, for example:
-> show /SP/faultmgmt
Targets:
shell
0 (/SYS/MB/P0)
Properties:
Commands:
cd
show
b. To clear the fault on processor 0, type the following command as an example:
-> set /SYS/MB/P0 clear_fault_action=true
For example:
-> set /SYS/MB/P0 clear_fault_action=true
Are you sure you want to clear /SYS/MB/P0 (y/n)? y
Set ‘clear_fault_action’ to ‘true’
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
REFERENCE INFORMATION:
Oracle Server X7-2 Service Manual:
https://docs.oracle.com/cd/E72435_01/html/E72445/index.html