Asset ID: |
1-71-2344893.1 |
Update Date: | 2018-01-02 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2344893.1
:
LRN not getting appended between CC and DN in the SCCP CDPA for ported out NON-SRI messages
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-16344691741>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 to EAGLE 46.5 [Release EAGLE 45.0 to EAGLE 46.0]
Information in this document applies to any platform.
Goal
LRN not getting appended between CC and DN in the SCCP CDPA for ported out NON-SRI messages.
Solution
G-Port performs the following actions based on the message received and number status:
If the message received is call-related SRI (not-SOR) and the number is ported-out, not known to be ported, or not identified to be ported, G-Port sends the SRI ack to the MSC with the Routing Number information in the MAP portion of the message.
If the number is ported-out and the message received is non-call related (non-SRI), G-Port performs a message relay function and forwards the translated message based on the Routing Number information.
If the number is non-ported or ported-in, G-Port performs an HLR translation and forwards the translated message to the HLR.
Below is the explanation for Message relay,
Message Relay describes how the EAGLE formulates a relayed message or a returned Ack.
Message Relay:-
The rules for formatting the SCCP CdPA GTA field are based on the value specified in the Digit Action field. If DigitAction = none, the EAGLE does not overwrite the SCCP CdPA GTA. For all other values, the EAGLE formats the SCCP CdPA GTA according to the value assigned to DigitAction. Refer to Table 4: DigitAction Applications for examples of DigitAction Expansion on the SCCP CdPA GTA of an outgoing message when the Entity ID = 1404 and the default country code = 886...
In this case the DigitAction for the ported out numbers was configured as "none" and hence no changes is done to the called party GTA.i.e LRN was not inserted between CC and DN.
Attachments
This solution has no attachment