![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2341763.1 : Apply Changes Failed In IMF
In this Document
Created from <SR 3-16413435961> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.5 and laterInformation in this document applies to any platform. GoalApply changes failing in IMF SolutionThe error message is happening because XX_MG_1 is monitoring 528 links which is beyond the threshold level of 512 and due to this we are getting error message while doing apply changes. 2017-12-18 15:39:24,508 - ERROR - xxxx-nsp - Centralized Configuration - tekelec - SYSTEM - Apply Error - com.steleus.nsp.config.system.exception.NSPCentConfException: Monitoring Group(s) xx_MG_x is invalid or exceeed capacity! Please correct before Applying Changes.
Please remove few linkset from monitoring and issue will resolve. Attachments This solution has no attachment |
||||||||||||||
|