Goal

Apply changes failing in IMF
 

Solution

The error message is happening because XX_MG_1 is monitoring 528 links which is beyond the threshold level of 512 and due to this we are getting error message while doing apply changes.

2017-12-18 15:39:24,508 - ERROR - xxxx-nsp - Centralized Configuration - tekelec - SYSTEM - Apply Error - com.steleus.nsp.config.system.exception.NSPCentConfException: Monitoring Group(s) xx_MG_x is invalid or exceeed capacity! Please correct before Applying Changes.

  
Each server is supporting a max of 512 links only.

Please remove few linkset from monitoring and issue will resolve.
 