Asset ID: |
1-71-2341454.1 |
Update Date: | 2017-12-24 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2341454.1
:
SL3000 - Unable To Connect New Ip Address SL3000
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-16389432531>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
unable to connect new ip address SL3000
Solution
1> Refer the following document to assign IP address
SL8500/SL3000 - How to Change the IP Address of a Library (Doc ID 1481492.1)
2> Verify the configuration
SL3000> network ip address show
2A:
Interface Status: UP
IPv4 Address/Netmask: 10.237.163.167/24
MAC Address: 00:10:4f:0d:e8:50
2B:
Interface Status: UP
IPv4 Address/Netmask: 10.60.77.32/24
MAC Address: 00:10:4f:0d:e8:4f
COMPLETED
SL3000> network print
Host Name: SL3000-TOTAL-DRC
Gateway: 10.237.163.254
2B IP Address: 10.60.77.32
2B Subnet Mask: 255.255.255.0
2B MAC Address: 00:10:4F:0D:E8:4F
2A IP Address: 10.237.163.167
2A Subnet Mask: 255.255.255.0
2A MAC Address: 00:10:4F:0D:E8:50
COMPLETED
SL3000> network ip route show
10.237.163.0/24 dev 2A
10.60.77.0/24 dev 2B
default via 10.237.163.254 dev 2A
COMPLETED
SL3000> network ip policy show
ERROR! syntax error at show
COMPLETED
SL3000> network ip policy status
2A:
Policy Rule: DISABLED
2B:
Policy Rule: DISABLED
COMPLETED
SL3000> network ip policy route show dev 2B
COMPLETED
SL3000> network ip policy route show dev 2A
COMPLETED
3>Try to ping library IP from other server
4>Try to ping or traceroute other IP from SL3000 library
5>Connect library to laptop using cross cable and try to ping
6>Change the network port in network switch
Attachments
This solution has no attachment