Goal
Solution


Created from <SR 3-16389432531>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

unable to connect new ip address SL3000
 

Solution

1> Refer the following document to assign IP address
SL8500/SL3000 - How to Change the IP Address of a Library (Doc ID 1481492.1)
2> Verify the configuration
SL3000> network ip address show

  2A:
  Interface Status: UP
  IPv4 Address/Netmask: 10.237.163.167/24
  MAC Address: 00:10:4f:0d:e8:50


  2B:
  Interface Status: UP
  IPv4 Address/Netmask: 10.60.77.32/24
  MAC Address: 00:10:4f:0d:e8:4f

COMPLETED

SL3000> network print
Host Name: SL3000-TOTAL-DRC
Gateway: 10.237.163.254
2B IP Address: 10.60.77.32
2B Subnet Mask: 255.255.255.0
2B MAC Address: 00:10:4F:0D:E8:4F

2A IP Address: 10.237.163.167
2A Subnet Mask: 255.255.255.0
2A MAC Address: 00:10:4F:0D:E8:50
COMPLETED

SL3000> network ip route show

10.237.163.0/24 dev 2A
10.60.77.0/24 dev 2B
default via 10.237.163.254 dev 2A

COMPLETED

SL3000> network ip policy show
ERROR! syntax error at show

COMPLETED

SL3000> network ip policy status

  2A:
  Policy Rule: DISABLED

  2B:
  Policy Rule: DISABLED

COMPLETED

SL3000> network ip policy route show dev 2B
COMPLETED

SL3000> network ip policy route show dev 2A
COMPLETED
3>Try to ping library IP from other server
4>Try to ping or traceroute other IP from SL3000 library
5>Connect library to laptop using cross cable and try to ping
6>Change the network port in network switch
 