Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2340489.1
Update Date:2018-05-24
Keywords:

Solution Type  Technical Instruction Sure

Solution  2340489.1 :   How to Disable the IPMI over LAN feature of the iLOM on BDA Servers  


Related Items
  • SPARC T4-1
  •  
  • Big Data Appliance X6-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>BDA>Big Data Appliance>DB: BDA_EST
  •  




In this Document
Goal
Solution


Created from <SR 3-16272399643>

Applies to:

Big Data Appliance X6-2 Hardware - Version All Versions to All Versions [Release All Releases]
SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
Linux x86-64

Goal

The procedure to disable the IPMI over LAN feature of the iLOM on BDA Servers.
 

Solution

BDA does not require the IPMI over LAN feature to be enabled.

1. To disable it from the server you want to disable the feature on ssh into the ILOM and login as 'root' user. 

2. Then follow the steps below:

# cd /SP/services
/SP/services
-> show

/SP/services
Targets:
http
https
ipmi
kvms
servicetag
snmp
ssh
sso
wsman

Properties:

Commands:
cd
show

-> show ipmi

/SP/services/ipmi
Targets:

Properties:
servicestate = enabled

Commands:
cd
set
show

-> set ipmi servicestate=disabled
Set 'servicestate' to 'disabled'
-> show ipmi

/SP/services/ipmi
Targets:

Properties:
servicestate = disabled

Commands:
cd
set
show

 

3. One disabled running any IPMI style command against the ILOM will no longer work.

 