Solution Type Technical Instruction Sure Solution 2326780.1 : Data to collect to provide support to verify Infiniband Fabric Quality
In this Document
Applies to:Sun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases]Sun Network QDR InfiniBand Gateway Switch - Version Not Applicable and later Information in this document applies to any platform. GoalWhat data to provide to diagnose Infiniband fabric quality issues. SolutionPlease run the following commands logged into ONLY ONE of the leaf switches and provide the requested files: # ibnetdiscover # ibdiagnet -skip dup_guids -ls 10 -lw 4x -pm (Collect all the files in /tmp that begin with ibdiagnet & provide these files) This will let us capture all of the pm counters since the last time the errors & counters were cleared. After the above command is run and the files collected, please run the following two commands to reset the counters & errors: # ibclearcounters Then run the following command: And collect another ibdiagnet: # ibdiagnet -skip dup_guids -ls 10 -lw 4x -pm Example: Once the information has been provided, please remove the ibdiagnet.1.tar & ibdiagnet.2.tar files from the switch.