Asset ID: |
1-71-2326734.1 |
Update Date: | 2017-11-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2326734.1
:
How to Correct The Amount of Links if All Are Displaying 0 on rtrv-upgrade-config:display=limsets Output?
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-16027537111>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 46.2 and later
Information in this document applies to any platform.
Goal
At executing Upgrade’s Procedure 30: Preparation for Upgrade to use the Card-Set Network Conversion Method and retrieving the card-set configuration with command rtrv-upgrade-config:display=limsets is seen that all links display 0 (zero) at upgrading Eagle STP while the values were correct on HC2. How to correct the amount of links if all are displaying 0 on rtrv-upgrade-config:display=limsets output?
> rtrv-upgrade-config:display=limsets
…
clli 17-10-28 02:39:27 TZ EAGLE 46.3.0.0.2-68.28.0 Upg Phase 0
Card List: Group = LINK, Set = 1
====================================
CARD APPL LINKS TPS
------------------------------------
1208 IPSG 0* N/A
1214 ATM 0 N/A
1216 IPSG 0* N/A
1304 ATM 0* N/A
1315 ATM 0* N/A
1316 ATM 0* N/A
2106 IPSG 0* N/A
2108 ATM 0* N/A
2111 SS7 0* N/A
2207 ATM 0* N/A
2208 ATM 0 N/A
2211 ATM 0* N/A
2212 ATM 0* N/A
2302 IPSG 0* N/A
2308 ATM 0* N/A
2315 IPSG 0* N/A
3108 ATM 0* N/A
3201 IPSG 0* N/A
3206 IPSG 0 N/A
3208 IPSG 0* N/A
3211 IPSG 0* N/A
3313 IPSG 0 N/A
3315 ATM 0* N/A
1104 IPSG 0 N/A
1112 IPSG 0 N/A
------------------------------------
ATM= 0%
IPSG= 0%
SS7= 0%
…
clli 17-10-28 02:39:39 TZ EAGLE 46.3.0.0.2-68.28.0 Upg Phase 0
Card List: Group = LINK, Set = 4
====================================
CARD APPL LINKS TPS
------------------------------------
1204 IPSG 0* N/A
1211 SS7 0* N/A
1215 ATM 0* N/A
1303 ATM 0* N/A
1305 IPSG 0* N/A
1311 IPSG 0* N/A
1312 ATM 0* N/A
1313 SS7 0* N/A
2103 SS7 0* N/A
2107 ATM 0* N/A
2115 ATM 0* N/A
2204 IPSG 0* N/A
2305 ATM 0* N/A
2313 ATM 0 N/A
3107 ATM 0* N/A
3113 ATM 0* N/A
3115 SS7 0* N/A
3202 IPSG 0* N/A
3203 SS7 0* N/A
3215 SS7 0* N/A
3217 IPSG 0* N/A
3303 ATM 0* N/A
3304 IPSG 0* N/A
3307 ATM 0* N/A
3311 IPSG 0* N/A
3314 IPSG 0* N/A
3316 IPSG 0* N/A
1101 IPSG 0* N/A
------------------------------------
ATM= 0%
IPSG= 0%
SS7= 0%
Solution
To correct the configuration execute next steps:
- Change Threshold Type from SET to GROUP:
chg-upgrade-config:threstype=group
- Change back Threshold Type from GROUP to SET:
chg-upgrade-config:threstype=set:srvsets=X:limsets=Y
- Create sets:
act-upgrade:action=createsets
- Verify changes:
act-upgrade:action=displaysets
rtrv-upgrade-config:display=sets
rtrv-upgrade-config:display=limsets
rtrv-upgrade-config:display=srvsets
Example after configuration correction:
> rtrv-upgrade-config:display=limsets
…
clli 17-10-28 03:45:00 TZ EAGLE 46.3.0.0.2-68.28.0 Upg Phase 0
Card List: Group = LINK, Set = 1
====================================
CARD APPL LINKS TPS
------------------------------------
1203 IPSG 0 N/A
1214 ATM 0 N/A
1216 IPSG 4 N/A
1304 ATM 2 N/A
1305 IPSG 4 N/A
1315 ATM 2 N/A
1316 ATM 2 N/A
2101 IPSG 1 N/A
2108 ATM 2 N/A
2111 SS7 32 N/A
2207 ATM 1 N/A
2208 ATM 0 N/A
2211 ATM 2 N/A
2212 ATM 1 N/A
2301 IPSG 0 N/A
2302 IPSG 0 N/A
2308 ATM 2 N/A
2316 IPSG 3 N/A
3103 IPSG 20 N/A
3108 ATM 2 N/A
3214 IPSG 2 N/A
3308 IPSG 3 N/A
3312 IPSG 4 N/A
3315 ATM 3 N/A
1112 IPSG 0 N/A
------------------------------------
ATM= 26%
IPSG= 25%
SS7= 31%
…
clli 17-10-28 03:45:11 TZ EAGLE 46.3.0.0.2-68.28.0 Upg Phase 0
Card List: Group = LINK, Set = 4
====================================
CARD APPL LINKS TPS
------------------------------------
1211 SS7 1 N/A
1215 ATM 2 N/A
1303 ATM 1 N/A
1311 IPSG 4 N/A
1312 ATM 1 N/A
1313 SS7 2 N/A
1318 IPSG 7 N/A
2103 SS7 2 N/A
2107 ATM 2 N/A
2115 ATM 2 N/A
2116 IPSG 4 N/A
2204 IPSG 6 N/A
2305 ATM 2 N/A
2313 ATM 0 N/A
3107 ATM 2 N/A
3113 ATM 2 N/A
3115 SS7 14 N/A
3203 SS7 2 N/A
3213 IPSG 2 N/A
3215 SS7 1 N/A
3217 IPSG 4 N/A
3218 IPSG 4 N/A
3301 IPSG 6 N/A
3303 ATM 2 N/A
3307 ATM 2 N/A
3316 IPSG 1 N/A
1101 IPSG 2 N/A
1111 IPSG 0 N/A
------------------------------------
ATM= 24%
IPSG= 24%
SS7= 21%
References
<NOTE:1597048.1> - Oracle Documentation Links
Attachments
This solution has no attachment