![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2324258.1 : DSR Alarm 25607 - DSR Signaling Firewall is Administratively Disabled
In this Document
Created from <SR 3-15964243491> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.4.0 and laterTekelec GoalAfter Upgrade to DSR 8.0.1 there is a new Signaling Firewall for the DA-MPs in SOAM GUI Main Menu: Diameter -> Maintenance -> Signaling Firewall. If the site cannot enable the firewall there is below mentionned alarm. How to disable the alarm? TIMESTAMP: 2017-10-26 02:04:36.494 EEST
NETWORK_ELEMENT: NE_SOAM SERVER: dsrSO-AAA-a SEQ_NUM: 49 EVENT_NUMBER: 25607 SEVERITY: MINOR PRODUCT: DSROAM PROCESS: dsroam TYPE: DIAM INSTANCE: dsrSO-AAA-a NAME: DSR Signaling Firewall is administratively Disabled DESCR: DSR Signaling Firewall is administratively Disabled. ERR_INFO: Condition may require attention if persists SolutionRefer to Procedure 39 on following document to enable firewall post upgrade. This will clear the alarm: Alarm cannot be cleared without enabling the signalling firewall. Customer can ignore this alarm if signalling firewall is not enabled. Refer to document CGBU_018537 DSR Diameter Signalling Firewall: R834837_MTCE_ALM_0010: When the firewall is administratively Disabled, a MINOR alarm 25607 shall be raised. The alarm shall be cleared when firewall gets Enabled. Enhancement Bug has been opened for firewall feature to support Multi homed SCTP connections as well: ENH Bug 26925068 - Signaling Firewall References<BUG:24406339> - DSR 8.0 UPGRADE DOC - MENTION EXPECTED ALARM 25607<BUG:26925068> - SIGNALING FIREWALL Attachments This solution has no attachment |
||||||||||||||||
|