Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2320381.1
Update Date:2017-11-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  2320381.1 :   SL4000 How to Replace the Safety Door Stop Switch Assembly  


Related Items
  • StorageTek SL4000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL4000 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

StorageTek SL4000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

 Safety Door Stop Switch Assembly Replacement

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Familiar with the SL4000 Library.
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 2

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW: The Switch Assembly has been determined defective and requires replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: Take the library offline to the system.

Note: Refer to the SL4000 Install and Service Manual for additional details as needed.

Safety Door Stop Switch Assembly Replacement
The stop switch detects that the safety door is lowered. The switch is fastened to a mounting block near the bottom of the safety door frame.
Required Tools
■ T25 driver

Removal
1. Take the library offline, and then open the Access Module door.
2. Remove the two T25 screws.
3. Pull back on the assembly to remove the mounting pins from the holes.
4. Disconnect P/J137/9.
5. Remove the switch and cable.

Replacement
1. Guide the cable through the opening in the extrusion.
2. Connect the P/J137/9.
3. Align the mounting pins with holes in the extrusion.
4. Install the two T25 screws.
5. Close the Access Module door, and then bring the library online.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Verify the switch and library initialize correctly and bring library online.

PARTS NOTE: Components List https://mosemp.us.oracle.com/handbook_internal/Systems/SL4000/components.html

REFERENCE INFORMATION: SL4000 Install and Service Manual: http://amomv0115.us.oracle.com/archive/cd_ns/E88746_01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.