In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

StorageTek SL4000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

 How to Replace the Library Storage (LOH) Card.

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Familiar with the SL4000 and LTO Tape Drive.
- TIME ESTIMATE: 15 minutes
- TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW: The LOH card has been determined defective and requires replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: This part can be hot swapped.
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Note: Refer to the SL4000 Install and Service Manual for additional details as needed.

Library Storage (LOH) Replacement
Required Tools
■ ESD protection

Removal
You can only hot-swap library storage hard drives. Do not remove a hard drive while the library is powered off.
1. Locate the faulty storage card (see"Base Card Cage Component Locations"onpage 4-11).
2. Pinch and pull the release levers. Remove the card (see "Removing a Quick Release Component" on page 4-9).

Replacement
1. Slide the new card into place and lock the release levers (see "Installing a Quick Release Component" on page 4-10). The OK light should begin flashing.
2. In the GUI, go to Hardware.
    - Locate the new card in the device status tree. The operational state should be "Rebuilding" as the library duplicates data from the other two storage cards. This process can take up to several hours.
3. Once the operational state of the card indicates "Normal", the replacement is complete.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Verify the library is functional.

PARTS NOTE: Components List https://mosemp.us.oracle.com/handbook_internal/Systems/SL4000/components.html

REFERENCE INFORMATION: SL4000 Install and Service Manual: http://amomv0115.us.oracle.com/archive/cd_ns/E88746_01/index.html