Created from <SR 3-15617342261> Applies to:SPARC T5-4 - Version All Versions and laterInformation in this document applies to any platform. Possible errors seen. Open failed, you must be the sole user! GoalUpdate the Hard Disk Firmware on a single disk rpool SolutionYou will need to boot off alternate media to accomplish the task. 1) Boot off cdrom or net (follow the document below) How to Mount the ZFS Root Pool (rpool) While Booted from CDrom / DVD Media or Network (Doc ID 1020186.1) 2) Copy over the Firmware Patch to the /tmp directory. How to Find Sun Hardware Disk Drive Firmware Patch in MOS (Doc ID 1294589.1) 3) Install the Hard Disk Firmware as per the README in the patch. 4) When finished, export the root pool. # cd / 5) Install the Firmware patch 6) Reboot
SymptomsIf you try to accomplish this while booted from single user mode or failsafe you can get the error: Open failed, you must be the sole user!
Changes
CauseThe Hard Disk Drive must not be in use to update the FW.