Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2314689.1
Update Date:2018-03-16
Keywords:

Solution Type  Technical Instruction Sure

Solution  2314689.1 :   How to Clear Event 32332 – HP Smart Array controller problem indicating Controller Battery/Capacitor Status Recharging  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution
References


Created from <SR 3-15745530111>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0 and later
Information in this document applies to any platform.

Goal

Goal of this article is to clear Event ID 32332 – HP Smart Array controller problem when syscheck on the server indicates "Controller in slot:0 Battery/Capacitor Status Recharging."

Solution

This is occasionally observed on HP based hardware, but is often just a reporting issue from the HP firmware.

To clear this condition, reboot the server in a maintenance window.

If a standard reboot fails to resolve the condition, re-seat the blade (or trip the E-Fuse through the c7000 Onboard Administrator) and allow full reboot.

To trip E-Fuse:

  1. ssh to OA
  2. on cli of OA run:
    a) show server names               (Note the server in question and the corresponding bay no.)     
    b) reset server <bay no. of server>      (bay no. of server obtained from previous command)

Failing that, the hardware should be replaced.

 

References

<NOTE:1902526.2> - Syscheck Errors
<NOTE:2259586.1> - Hpacuclistatus Alarm On DSR Server Alarm ID EVENT_NUMBER: 32333

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.