![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2314689.1 : How to Clear Event 32332 – HP Smart Array controller problem indicating Controller Battery/Capacitor Status Recharging
In this Document
Created from <SR 3-15745530111> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0 and laterInformation in this document applies to any platform. GoalGoal of this article is to clear Event ID 32332 – HP Smart Array controller problem when syscheck on the server indicates "Controller in slot:0 Battery/Capacitor Status Recharging." SolutionThis is occasionally observed on HP based hardware, but is often just a reporting issue from the HP firmware. To clear this condition, reboot the server in a maintenance window. If a standard reboot fails to resolve the condition, re-seat the blade (or trip the E-Fuse through the c7000 Onboard Administrator) and allow full reboot. To trip E-Fuse:
Failing that, the hardware should be replaced.