Solution Type  Technical Instruction Sure

Solution  2308800.1 :   HP LTO5-7 - How to use HPE L&TT diagnostics tool via Ethernet mode.  


Related Items
  • HP LTO6 Tape Drive
  •  
  • HP LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Applies to:

HP LTO6 Tape Drive - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Goal

HPE LTO-5, LTO-6, and LTO-7 library tape drives support drive diagnostics via the Ethernet interface using the Internet Diagnostics Tool Interface (iDTI) protocol.

L&TT 4.14 and newer releases support this feature with the Ethernet mode.

With Ethernet mode,most diagnostics can be performed from a laptop (with L&TT installed) that is connected to the drive or library with an Ethernet cable.

This saves installing L&TT on a specific server and connecting to the drive or library with SCSI cables.

Solution

Steps :

1. Open HP L&TT (Run as Administrator)
2. Scan Mode - Hardware Scan
3. I/O Mode - Ethernet
4. Select "IP address" in drop-down box
5. Enter the drive IP address
6. Continue.

How to Collect Statistical and Error Logs from HP LTO Tape Drive Using HP LTT:ATR:1185771.1:1 (Doc ID 1185771.1)