Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2308635.1
Update Date:2017-09-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  2308635.1 :   SL4000 - Front Door Switch Replacement  


Related Items
  • StorageTek SL4000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL4000 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

StorageTek SL4000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

 How to replace the Front Door Switch on SL4000 library.

Solution

 DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Familiar with the SL4000 library.
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 2

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW: The Front Door Switch has been determined defective and requires replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: Library must be offline to the system.
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Note: Refer to the SL4000 Install and Service Manual for additional details as needed.

When you order the front door switch cable, you will also receive the switch. The front door switch is located on the front of each Base and Drive Module frame.

Removal
1. Take the library offline, and then open the front door of the module.
2. On the inside of the door frame, disconnect J521 at the end of the switch cable.
3. Squeeze the sides of the switch, and then push the switch and cable out through the front of the frame.

Replacement
1. Reverse the removal procedures.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Bring the library back online to the system and verify the front door switch is functional.

PARTS NOTE: Components List https://mosemp.us.oracle.com/handbook_internal/Systems/SL4000/components.html

REFERENCE INFORMATION: SL4000 Install and Service Manual http://amomv0115.us.oracle.com/archive/cd_ns/E88746_01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback