Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2302195.1
Update Date:2017-08-31
Keywords:

Solution Type  Technical Instruction Sure

Solution  2302195.1 :   E5MS 46.3 License Application Failure (ERROR CODE : 507 The license file specified is not valid.)  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-15636679001>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 46.3 and later
Tekelec

Goal

Following error message is received when applying the license file to a fresh install of OCEEMS 46.3.

ERROR CODE : 507
The license file specified is not valid.
Please contact
  Oracle
  5200 Paramount Parkway,
  Morrisville, NC 27560 USA

Solution

The startnms script has been performed from new non-root admin user emsadmuser

[emsadmuser@oceemshost bin]$ sh startnms.sh

The license file is owned by user root and does not have permissions for other users

[root@oceemshost ~]# ll /tmp
total 4
-rw------- 1 root root 2841 Aug 28 16:28 46.xml

Perform chmod on license file so that the non-root admin user emsadmuser can use it for applying license

chmod 777 /tmp/46.xml

Attachments