Asset ID: |
1-71-2295459.1 |
Update Date: | 2017-08-14 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2295459.1
:
Fujitsu SPARC M12-1/M12-2/M12-2S Servers: System LED Descriptions
Related Items |
- Fujitsu SPARC M12-2S
- Fujitsu SPARC M12-1
- Fujitsu SPARC M12-2
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M12
|
In this Document
Applies to:
Fujitsu SPARC M12-1 - Version All Versions and later
Fujitsu SPARC M12-2 - Version All Versions and later
Fujitsu SPARC M12-2S - Version All Versions and later
Information in this document applies to any platform.
Goal
Define the location and meaning of the different system LEDs.
Solution
Fujitsu M12-1 OPNL LEDs and Switches
M12-1 Front LED and Switch Descriptions
Icon |
LED Name |
LED Color |
Description |
 |
Power LED |
Green |
- On - System is up and running
- Blinking - System stop in progress
- Off - System is stopped and/or not powered on
|
 |
XSCF Standby |
Green |
- On - XSCF is functioning normally
- Blinking - System initialization is in progress after power has been turned on
- Off - XSCF is stopped
|
 |
Check LED |
Amber |
- Steady On - An error has been detected
- Blinking - Indicates that the cabinet should be maintained. (this function is also referred to as a locator.)
- Off - The system is in a normal state, power is disconnected or not being supplied
|

|
Locked Mode
|
Specifies the operation mode |
- This mode is used in a normal operation. The power switch can start the system but cannot stop it.
|
 |
Service Mode
|
Specifies the operation mode |
This is used during maintenance.
- The power switch can start and stop the system.
- Set the system to the Service mode when performing maintenance work.
|
 |
Power button |
Start/Stop |
- Press - Less than 4 seconds,
- if the system is stopped in locked mode the system starts
- Press - More than 4 seconds,
- If the system was started in Service mode: Perform the system shutdown process to stop the system.
- If the system startup process is in progress in Service Mode: Cancels the system startup process and stops the system.
- If the system stop process is in progress in Service mode: Continues the system stop process
- If the system is stopped in Service mode: Operation is ignored. Even a long press does not start the system.
- If the system is stopped in Locked mode: Starts the system. If a wait time for the air conditioning facilities or a warm-up time is set on the XSCF, the
processing for waiting for the power-on of the air conditioning facilities and the completion of warm-up is omitted.
|
Fujitsu M12-1 Rear Panel LEDs
LED location highlighted in red.

M12-1 Rear LED Descriptions
Number |
LED Name |
LED Color |
Description |
1 |
System Locator LED |
Amber |
System Locator LED - used to identify system in a rack.
- Has the same functionality as the CHECK LED on the OPNL
|
2 |
XSCF Ready LED |
Green |
- On - The XSCF is operating
- Blinking - XSCF is initializing
- Off - Component is powered off
|
3 |
XSCF Check LED |
Amber |
- On - Indicates an error has occurred
- Blinking - Indicates that the component requires maintenance ( aka locator )
- Off - Normal state
|
Fujitsu M12-2 & M12-2S OPNL LEDs and Switches

M12-2/2S Front LED and Switch Descriptions
Icon |
LED Name |
LED Color |
Description |
 |
Power LED |
Green |
- On - System is up and running
- Blinking - System stop in progress
- Off - System is stopped and/or not powered on
|
 |
XSCF Standby |
Green |
- On - XSCF is functioning normally
- Blinking - System initialization is in progress after power has been turned on
- Off - XSCF is stopped
|
 |
Check LED |
Amber |
- Steady On - An error has been detected
- Blinking - Indicates that the cabinet should be maintained. (this function is also referred to as a locator.)
- Off - The system is in a normal state, power is disconnected or not being supplied
|

|
Locked Mode
|
Specifies the operation mode |
- This mode is used in a normal operation. The power switch can start the system but cannot stop it.
|
 |
Service Mode
|
Specifies the operation mode |
This is used during maintenance.
- The power switch can start and stop the system.
- Set the system to the Service mode when performing maintenance work.
|
 |
Power button |
Start/Stop |
- Press - Less than 4 seconds,
- if the system is stopped in locked mode the system starts
- Press - More than 4 seconds,
- If the system was started in Service mode: Perform the system shutdown process to stop the system.
- If the system startup process is in progress in Service Mode: Cancels the system startup process and stops the system.
- If the system stop process is in progress in Service mode: Continues the system stop process
- If the system is stopped in Service mode: Operation is ignored. Even a long press does not start the system.
- If the system is stopped in Locked mode: Starts the system. If a wait time for the air conditioning facilities or a warm-up time is set on the XSCF, the
processing for waiting for the power-on of the air conditioning facilities and the completion of warm-up is omitted.
|
Fujitsu M12-2 & M12-2S Rear Panel LEDs

M12-2/2S Rear LED Descriptions
LED Name |
LED Color |
Description |
System Locator LED |
Amber |
System locator LED - used to identify system in a rack. |
Power LED |
Green |
System is running; a system shutdown is in progress: system is stopped and/or not powered on. |
Check LED |
Amber |
Indicates the operation status of the SPARC M12-2/M12-2S.
- On: Hardware has detected an error.
- Off: The target SPARC M12-2/M12-2S is operating normally. Or it is not powered on.
- Blinking: Maintenance work is in progress for the target SPARC M12-2/M12-2S.
|
Attachments