Goal

How to Replace a SPARC T8-4 Rear Chassis Subassembly (RCSA)

Solution

 

*************************************************************************************
o report errors or request improvements on this procedure, please add a comment on Doc ID: 2295126.1
*************************************************************************************

ESD Caution:

  • Circuit boards and drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat.

Contamination Caution:

    • Dust particles of packaging material are number one cause of datacenter contamination. Make sure to remove all packaging material, up to the ESD safe packaging material, while still being outside the datacenter.

 

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: SPARC T8-4 Product Training required, to be serviced by qualified Oracle Service personnel, requires the ability to follow steps similar to what is in the Product Service manual.

Time Estimate: 90 minutes

Task Complexity: 1

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: SPARC T8-4 Rear Chassis Subassembly (RCSA) Replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

NOTE:
  • A data backup is not a prerequisite but is a wise precaution.
  • If the system is still up and functioning, the Customer should perform an orderly and graceful shutdown of the applications and operating system.
  • Then power off the server and remove the AC power cords from the system. For ALL scenarios where an AC power down or AC power cycle is required for a T8-x server, please always use the steps in doc 1571054.1 prior to physically removing AC power cables from the server.

 

WHAT ACTIONS ARE REQUIRED?:

Damage Alert:

  • Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.

 

Replace the Rear Chassis Subassembly (RCSA)

1. Log into the ILOM and check the fruid container values and sync them if needed.

    a. To avoid mismatched fruid values causing a failure after a Rear Chassis Subassembly (RCSA) replacement the fruid data should be confirmed to have matching data in at least the Backup1 (SPM) and Backup2 (FIO; Front I/O Module) containers so that the RCSA will have it's container updated automatically after replacement. Go into restricted mode and use the showpsnc command to check this.     

           -> set SESSION mode=restricted

           WARNING: The "Restricted Shell" account is provided solely to allow Services to perform diagnostic tasks.

           [(restricted_shell) bur-t84-315-sp:~]# showpsnc
           Primary: fruid:///SYS/RCSA
           Backup 1: file:///persist/psnc_backup1.xml
           Backup 2: fruid:///SYS/FIO

           Element              |   Primary               |    Backup1              |    Backup2
          --------------------+-----------------------+-----------------------+------------------------------
           PPN                       33948194+1+2          33948194+1+2          33948194+1+2
           PSN                       AK00344096              AK00344096              AK00344096
           MACADDR              00:10:E0:C0:9C:76    00:10:E0:C0:9C:76    00:10:E0:C0:9C:76
           HOSTID                 86c09c76                  86c09c76                   86c09c76
           Product Name         SPARC T8-4              SPARC T8-4               SPARC T8-4
           RFID SN                 341A583DE580000000018808 341A583DE580000000018808 341A583DE580000000018808
           [(restricted_shell) bur-t84-315-sp:~]# exit    

     b. The above example shows a system with all three containers properly in sync. If the output from the system does not show all of the containers with matching values then you should reset the SP and then re-check the values again. An ILOM reset will attempt to auto-populate the matching values if one container is out of sync.  

       -> reset /SP
          Are you sure you want to reset /SP (y/n)? y
          Performing reset on /SP

     c. After an SP reset if the Backup1 and Backup2 containers match then proceed with the following steps to replace the RCSA. If these two containers do not match then DO NOT proceed with the replacement yet.
     d. If the containers do not match you will need to use the copypsnc command from service or escalation mode to copy the data from the good container so that the Backup1 and Backup2 containers match (Primary is the RCSA and we are about to replace this so it is not as important at this step).

If you are unfamiliar with this process and require assistance please reference the steps for using copypsnc to fix the serial number detailed in the "How to update product serial number on systems which implement TLI functionality (Doc ID 1280913.1)" and contact the TSC if needed. How to access service mode and escalation mode on ILOM 3.x and later platforms (Doc ID 1019946.1).
     e. After the fruid data in the Backup1 and Backup2 containers have been confirmed to match proceed with the following steps.

2. Prepare the server for service.

    a. Power off the server and disconnect the power cords from the power supplies.
    b. Attach an anti-static wrist strap.

3. Go to the rear of the server and remove the following components:

    a. All five fans
    b. All PCIe carriers (being used or not). Make note of the slots for each carrier so that you can install them into the same slots after replacement.
    c. Rear I/O module (RIO) 

Note - You will install these components into the replacement rear chassis subassembly once you have replaced the faulty one.

4. Go to the front of the server and remove the following components:

    a. Both processor modules or processor filler modules
    b. Main module motherboard
    c. All four power supplies

5. Locate the eight green mounting screws that secure rear chassis subassembly (RCSA).

6. Using a Phillips screwdriver, loosen the eight screws that secure the rear chassis subassembly (RCSA) to the system chassis.

7. Slide the rear chassis subassembly (RCSA) out and away from the server.

8. Slide the replacement rear chassis subassembly (RCSA) into the rear of the server.

9. Using a Phillips screwdriver, tighten the eight green screws to secure the rear chassis subassembly (RCSA) in the server.

    a. Tighten the screws in the following order: 

Note - Tighten each screw a couple turns in the order below and then repeat until all eight screws are fully tightened.

        Lower right outside screw.

        Upper left outside screw.

        Upper right outside screw.

        Lower left outside screw.

        Lower right inside screw.

        Upper left inside screw.

        Upper right inside screw.

        Lower left inside screw.

10. Remove the connector covers from the replacement rear chassis subassembly (RCSA).

11. Install all four power supplies, main module, and processor modules that were removed from the front of the server.

12. Install the following components back into the rear of the server:

    a. All five fans
    b. All PCIe carriers. Verify that you are installing the PCIe cards back in their original slots using the notes that you took when removing the cards from the slots earlier.
    c. Rear I/O module 

13. Return the Server to operation.

    a. Remove any anti-static measures that were used.
    b. Re-install the AC power cords and any data cables that were removed.
    c. Power on server. Verify that the Power/OK indicator led lights steady on.

14. Set the system serial number/fruid data, if needed.

     a. The RCSA is the primary fruid container in this server so when it is replaced you will normally need to fix the serial number information (TLI).
     b. login to the ILOM as root and then enter the "restricted shell" to check the fruid values. Follow the example below to enter restricted shell and use the showpsnc command:    

         -> set SESSION mode=restricted

           WARNING: The "Restricted Shell" account is provided solely to allow Services to perform diagnostic tasks.

           [(restricted_shell) bur-t84-315-sp:~]# showpsnc
           Primary: fruid:///SYS/RCSA
           Backup 1: file:///persist/psnc_backup1.xml
           Backup 2: fruid:///SYS/FIO

           Element              |     Primary                |     Backup1                      |    Backup2
          ------------------+----------------------+--------------------------+------------------------------
           PPN                         33948194+1+2             33948194+1+2                  33948194+1+2
           PSN                         0000000000                AK00344096                      AK00344096
           MACADDR                00:10:E0:C0:9C:76      00:10:E0:C0:9C:76           00:10:E0:C0:9C:76
           HOSTID                   86c09c76                    86c09c76                          86c09c76
           Product Name           SPARC T8-4                SPARC T8-4                       SPARC T8-4
           RFID SN                   341A583DE580000000018808 341A583DE580000000018808 341A583DE580000000018808
           [(restricted_shell) bur-t84-315-sp:~]# exit

     c. When the RCSA is replaced the Primary fruid container will likely not match the Backup entries. If it does not you must enter escalation or service mode to fix it (if all three entries match this step is done).
     d. Contact the TSC to request an escalation password (service mode will work also if just the copypsnc command ends up needing to be used, if the setpsnc command is needed escalation mode is required. setpsnc is not covered in this procedure).
     e. Provide your TSC contact the output from the following ILOM commands- "version", "show /SYS product_serial_number", and "show /SP/clock". If the product_serial_number information does not give good output then provide the showpsnc output that was seen in step b above as well.
     f. The TSC will provide an escalation password that is made up of 32 short words. Follow the example below to create a new user with the 'Service' role assigned. The Service role is required to access service or escalation modes. In the following example we will create a user named 'escuser' with the service role.       

     -> cd /SP/users
     /SP/users
     -> create escuser
     Creating user...
     Enter new password: ********
     Enter new password again: ********
     Created /SP/users/escuser
     -> set escuser role=aucros
     Set 'role' to 'aucros'
     -> show escuser
     /SP/users/escuser
     Targets:
     ssh
     Properties:
     role = aucros
     password = ***** 

      g. Set the check_physical_presence to false and then exit from the ILOM so that you can login as the newly created user.            

  -> set /SP check_physical_presence=false
     Set 'check_physical_presence' to 'false'
     -> show /SP check_physical_presence
     /SP
     Properties:
     check_physical_presence = false
     -> exit

      h. Login using the escuser login and enter escalation mode using the password that was provided by the TSC.                  

     bur-t84-315-sp login: escuser
     Password:

     Oracle(R) Integrated Lights Out Manager

     Version 4.0.1.2.dev r120300

     Copyright (c) 2017, Oracle and/or its affiliates. All rights reserved.

     Warning: The system appears to be in manufacturing test mode.
     Contact Service immediately.

     Hostname: bur-t84-315-sp

     -> cd /SP/users/escuser/escalation
     -> set SESSION mode=escalation                          
     Password:**** **** **** **** **** *** *** **** **** **** **** **** **** **** **** **** *** *** **** *** **** **** **** *** **** **** *** **** *** *
     Short form password is:  NOSE HAAG MED

     [(escalation_mode) bur-t84-315-sp:~]#

     i. Use the showpsnc command to confirm the current container values. Confirm that the primary container has a serial number (the value on the PSN line) that matches the system serial number. The system serial number can be checked by comparing to the serial number RFID tag on the front left hand side of the server. After confirming that there is a valid fruid backup use the copypsnc command to write the good data from the backup to the primary container on the RCSA. The following example shows copying from backup1 to the primary but you could also copy from backup2 if needed.       

           [(restricted_shell) bur-t84-315-sp:~]# showpsnc
           Primary: fruid:///SYS/RCSA
           Backup 1: file:///persist/psnc_backup1.xml
           Backup 2: fruid:///SYS/FIO

           Element              |   Primary               |    Backup1              |    Backup2
          --------------------+-----------------------+-----------------------+------------------------------
           PPN                       33948194+1+2          33948194+1+2          33948194+1+2
           PSN                       0000000000              AK00344096              AK00344096
           MACADDR              00:10:E0:C0:9C:76    00:10:E0:C0:9C:76    00:10:E0:C0:9C:76
           HOSTID                 86c09c76                  86c09c76                   86c09c76
           Product Name         SPARC T8-4              SPARC T8-4               SPARC T8-4
           RFID SN                 341A583DE580000000018808 341A583DE580000000018808 341A583DE580000000018808
           [(restricted_shell) bur-t84-315-sp:~]# copypsnc Backup1 Primary

           [(restricted_shell) bur-t84-315-sp:~]# showpsnc
           Primary: fruid:///SYS/RCSA
           Backup 1: file:///persist/psnc_backup1.xml
           Backup 2: fruid:///SYS/FIO

           Element              |   Primary               |    Backup1              |    Backup2
          --------------------+-----------------------+-----------------------+------------------------------
           PPN                       33948194+1+2          33948194+1+2          33948194+1+2
           PSN                       AK00344096              AK00344096              AK00344096
           MACADDR              00:10:E0:C0:9C:76    00:10:E0:C0:9C:76    00:10:E0:C0:9C:76
           HOSTID                 86c09c76                  86c09c76                   86c09c76
           Product Name         SPARC T8-4              SPARC T8-4               SPARC T8-4
           RFID SN                 341A583DE580000000018808 341A583DE580000000018808 341A583DE580000000018808
           [(restricted_shell) bur-t84-315-sp:~]# exit    

     j. At this point if all of the fruid containers match and have the correct serial number data this step is done. If more than one of the fruid containers had non-valid entries then the copypsnc command should be used to copy over the valid data to the other container that is not valid. (ie. "copypsnc Backup1 to Backup2") After confirming all fruid data is correct reset the ILOM to confirm that the fruid data persists through a reboot and remove the escalation user if needed. 

     -> reset /SP
     Are you sure you want to reset /SP (y/n)? y
     Performing reset on /SP
     ..........

     ***login as the root user again and check the fruid data***

     -> set SESSION mode=restricted

     WARNING: The "Restricted Shell" account is provided solely to allow Services to perform diagnostic tasks.

           [(restricted_shell) bur-t84-315-sp:~]# showpsnc
           Primary: fruid:///SYS/RCSA
           Backup 1: file:///persist/psnc_backup1.xml
           Backup 2: fruid:///SYS/FIO

           Element              |   Primary               |    Backup1              |    Backup2
          --------------------+-----------------------+-----------------------+------------------------------
           PPN                       33948194+1+2          33948194+1+2          33948194+1+2
           PSN                       AK00344096              AK00344096              AK00344096
           MACADDR              00:10:E0:C0:9C:76    00:10:E0:C0:9C:76    00:10:E0:C0:9C:76
           HOSTID                 86c09c76                  86c09c76                   86c09c76
           Product Name         SPARC T8-4              SPARC T8-4               SPARC T8-4
           RFID SN                 341A583DE580000000018808 341A583DE580000000018808 341A583DE580000000018808
           [(restricted_shell) bur-t84-315-sp:~]# exit    



     -> cd /SP/users
     /SP/users
     -> delete escuser
     Are you sure you want to delete /SP/users/escuser (y/n)? y
     Deleted /SP/users/escuser

     k. If trouble is encountered during any of the steps of accessing escalation mode and fixing the fruid containers please contact the TSC for assistance.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE FE/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
     component faults.
   * If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.


PARTS NOTE: 
https://support.oracle.com/handbook_partner/Systems/SPARC_T8_4/components.html#Chassis



REFERENCE INFORMATION:
SPARC T8-4 Service Manual: https://docs.oracle.com/cd/E79179_01/html/E80512/index.html

 

Save

Save

References

<NOTE:1280913.1> - How to update System, Chassis, and Product level Key Identity Properties on ILOM based systems which implement Top Level Identifier (TLI) functionality
<NOTE:1019946.1> - How to access service mode and escalation mode on ILOM 3.x and later platforms
<NOTE:1571054.1> - Performing an AC power cycle on the T3/T4/T5/S7/T7/T8 Servers

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback