Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2294443.1
Update Date:2018-01-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  2294443.1 :   Procedure to access EAGLE STP MMI port from E5-APP-B  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Goal
Solution


Created from <SR 3-15327108881>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EPAP 16.0 and later
Tekelec

Goal

How to access EAGLE STP MMI port from E5-APP-B card?
 

Solution

1. Please make sure the required cable connectivity is done between P5 serial port (ttyS2) of EPAP-B and the MMI port (any MMI port) of EAGLE.

Note:- The following cable/adapter are required to do the connection (830-1423-XX – Adapter for the back of the STP and 830-1212-XX – Cable to connect from the ttyS2 of the APP-B adapter to the back of the 830-1423-XX STP adapter.) Without these exact cables, the connection to the MMI will not work.

2. Please make sure P5 serial port (ttyS2) is configured in EPAP-B.


· remoteConsole --query

· remoteConsole --add --name=eagle --bps=9600 --port=ttyS2 --databits=7 --parity=E

· remoteConsole --query

· remoteConsole --query --name=eagle

. pkill -9 agetty

. pkill -9 mingetty

. pkill -9 minicom


After the above two requirements are met, execute the below command to access the EAGLE MMI port from EPAP-B.

minicom eagle

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback