Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2293002.1
Update Date:2017-08-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  2293002.1 :   Standby E5MASP OAMHC GPL is not running approved version  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-15453101789>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 45.0 and later
Information in this document applies to any platform.

Goal

Problem Details:
============
STB E5MASP is running non approved OAMHC GPL Version

Capture
========

  GPL   CARD RUNNING         APPROVED     TRIAL
  OAMHC 1113 138-027-000 ALM 138-029-000  ----------- *
  OAMHC 1115 138-029-000     138-029-000  ----------- *

 

Solution

The E5MASP loads OAMHC GPL from backup USB drive (IF inserted). In case the backup USB had OLD Release GPL versions and IF card boots then it could make it load old version.

Following actions can be performed to correct the OAMHC GPL on STB E5MCAP - which is location 1113 in this case:

  1. Please, insert backup USB drive in E5MCAP 1113 (make sure the backup USB drive has correct GPL versions copied for system current Release)
  2. Reboot the STB E5MCAP (1113) using command (init-card:loc=xxx)
  3. Please, wait for card to get back in service normal (rept-stat-card:mode=full:loc=xxx)
  4. Verify the OAMHC GPL versions: rept-stat-gpl:gpl=oamhc

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback