Asset ID: |
1-71-2288051.1 |
Update Date: | 2017-08-06 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2288051.1
:
EPAP - Remote PDB Address Configuration Issue
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-15309802321>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 15.0 and later
Information in this document applies to any platform.
Goal
There are two remote PDB address configured as below in this non-prov EPAP.
1. 10.xx.yy.zz
2. 10.aa.bb.cc
Here the second address 10.aa.bb.cc was incorrect and customer wanted to correct it (which should be belongs to another PDB site in the network).
Solution
Correct the worng PDB address using the epapconfig menu under option 8 (PDB Menu) and provide the correct ip address. You need to enter both the PDB address again.
Post changes display the configuration and make sure that changes are reflected.
MPS Side A: hostname: mps-xyz-a hostid: 0a0a4zas
Platform Version: 4.0.10-5.5.0_75.13.0
Software Version: EPAP 150.0.23-15.0.2_150.27.0
Tue Jul 11 00:09:27 XYZ 2017
EPAP A Provisioning Network IP Address = xx.xx.xx.xx
EPAP B Provisioning Network IP Address = xx.xx.xx.xx
Provisioning Network Netmask = xx.xx.xx.xx
Provisioning Network Default Router = xx.xx.xx.xx
EPAP A Backup Prov Network IP Address = Not configured
EPAP B Backup Prov Network IP Address = Not configured
Backup Prov Network Netmask = Not configured
Backup Prov Network Default Router = Not configured
EPAP A Sync Network Address = 192.168.2.100
EPAP B Sync Network Address = 192.168.2.200
EPAP A Main DSM Network Address = 192.168.120.100
EPAP B Main DSM Network Address = 192.168.120.200
EPAP A Backup DSM Network Address = 192.168.121.100
EPAP B Backup DSM Network Address = 192.168.121.200
EPAP A HTTP Port = 80
EPAP B HTTP Port = 80
EPAP A HTTP SuExec Port = 8001
EPAP B HTTP SuExec Port = 8001
EPAP A Banner Connection Port = 8473
EPAP B Banner Connection Port = 8473
EPAP A Static NAT Address = Not configured
EPAP B Static NAT Address = Not configured
PDBI Port = 5873
Remote MPS A Static NAT Address = Not configured
Remote MPS A HTTP Port = 80
PDBA Addresses = 10.xx.yy.zz
= 10.a1.b1.c1 ( <--corrected one)
Time Zone = America/xxx
PDB Database = None - Non-provisionable Site
Preferred PDB = 10.xx.yy.zz
Allow updates from alternate PDB = Yes
Restart the GS process post changes and verify the "View RTDB". It should shows both the PDB status as connected with correct addresses of PDB sites and all the db is coherent state.
Attachments