![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2285333.1 : Fujitsu M12-1: How to Replace a Power Supply ( PSU ) [VCAP]
M10-1 - CAP for power supply replacement In this Document
Applies to:Fujitsu SPARC M12-1 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalM12-1 server - How to replace a power supply Solution
DISPATCH INSTRUCTIONS - WHAT SKILLS ARE REQUIRED?:No special skills required, Customer Replaceable Unit (CRU) procedure - TIME ESTIMATE: 20 minutes - TASK COMPLEXITY: 0 REMOVAL/REPLACEMENT INSTRUCTIONS: - PROBLEM OVERVIEW: - WHAT STATE SHOULD THE SYSTEM BE IN PRIOR TO PERFORMING THE RESOLUTION ACTIVITY?: This activity can be performed as either an active/hot replacement or a cold replacement. - WHAT ACTIONS ARE REQUIRED?: Active Replacement: 1. Log in to XSCF and execute the replacefru command. ( Must have fieldeng permissions ) Physical removal of the power supply Physical installation of the power supply Cold Replacement Other than powering down the server, there are no special steps for cold replacement. Once the server has been powered down, perform the physical removal and physical installation procedures as outlined above OBTAIN CUSTOMER ACCEPTANCE No additional work is required For a complete procedure, please see the M12-1 service manual
Attachments This solution has no attachment |
||||||||||||||
|