![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2273325.1 : FS System: How to Gather Configuration Data From Controller ILOM
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalTo document various ILOM commands to provide helpful configuration data about an FS1-2. SolutionThe following commands can be used to gather configuration information about an FS1-2. They are typically run from a Controller (as is the case in all of the examples below) but are also valid for running on Pilots.
The hwdiag command is specific to targets that can be seen by the ILOM. An example of hwdiag system info all:
The command hwdiag pci scan provides details about what the system can see on the PCIe bus. In particular examine the SKT[0] section for PCIe entries. Anything listed should be "ACTIVE". Slots that are not listed are empty. Slots that show "off" are indicative of problems. A single "off" instance would be indicative of either the PCIe card itself or the riser it is plugged into. If both PCIe cards on the same riser are "off", that points more towards the riser or worse, the system board. [(restricted_shell) ORACLESP-1315FM2008:~]# hwdiag pci scan HWdiag (Restricted Mode) - Build Number 109399 (Apr 08 2016, 20:00:47) Current Date/Time: Jun 12 2017, 18:15:09 SKT[0]_ `-[00]---00.0 {did:3c00 vid:8086 (Intel Corporation) rid:07 cc:060000 svid:108e (Oracle/SUN) sid:484f} `-[00]-+-11.0----[6a] {did:1d3e vid:8086 (Intel Corporation) rid:06 cc:060400 svid:108e (Oracle/SUN) sid:484F} `-[00]---1a.0 {did:1d2d vid:8086 (Intel Corporation) rid:06 cc:0c0320 svid:108e (Oracle/SUN) sid:484f} `-[00]-+-1c.0----[5c-5f] {did:1d10 vid:8086 (Intel Corporation) rid:b6 cc:060400 svid:108e (Oracle/SUN) sid:484F} `-[5c]-+-00.0----[5d-5f] {did:8039 vid:111d (Integrated Device Technology, Inc.) rid:0e cc:060400 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} `-[5d]-+-02.0----[5e] {did:8039 vid:111d (Integrated Device Technology, Inc.) rid:0e cc:060400 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} : ACTIVE - (x1 @ 2.5GT/s) `-[5e]---00.0 {did:c20c vid:1415 (Oxford Semiconductor Ltd) rid:00 cc:088000 svid:108e (Oracle/SUN) sid:7b07} `-[5e]---00.1 {did:c20d vid:1415 (Oxford Semiconductor Ltd) rid:00 cc:070006 svid:108e (Oracle/SUN) sid:7b07} `-[5d]-+-03.0----[5f] {did:8039 vid:111d (Integrated Device Technology, Inc.) rid:0e cc:060400 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} : ACTIVE - (x1 @ 2.5GT/s) `-[5f]---00.0 {did:107d vid:8086 (Intel Corporation) rid:06 cc:020000 svid:108e (Oracle/SUN) sid:7b07} `-[00]-+-1c.7----[61-62] {did:1d1e vid:8086 (Intel Corporation) rid:b6 cc:060400 svid:108e (Oracle/SUN) sid:484F} `-[61]-+-00.0----[62] {did:1150 vid:1a03 (ASPEED Technology, Inc.) rid:02 cc:060400 svid:1a03 (ASPEED Technology, Inc.) sid:1150} : *off* `-[62]---00.0 {did:2000 vid:1a03 (ASPEED Technology, Inc.) rid:21 cc:030000 svid:108e (Oracle/SUN) sid:484f} `-[00]---1d.0 {did:1d26 vid:8086 (Intel Corporation) rid:06 cc:0c0320 svid:108e (Oracle/SUN) sid:484f} `-[00]---1f.0 {did:1d41 vid:8086 (Intel Corporation) rid:06 cc:060100 svid:108e (Oracle/SUN) sid:484f} `-[00]---1f.2 {did:1d02 vid:8086 (Intel Corporation) rid:06 cc:010601 svid:108e (Oracle/SUN) sid:484f} `-[00]---1f.3 {did:1d22 vid:8086 (Intel Corporation) rid:06 cc:0c0500 svid:108e (Oracle/SUN) sid:484f} `-[00]---1f.6 {did:1d24 vid:8086 (Intel Corporation) rid:06 cc:118000 svid:108e (Oracle/SUN) sid:484f} `-[00]-+-01.0----[00] {did:3c02 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:8086 (Intel Corporation) sid:0000} : PCH - *off* `-[00]-+-02.0----[20] {did:3c04 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 1 - ACTIVE - (x8 @ 5.0GT/s) `-[20]---00.0 {did:10fb vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:7b11} `-[20]---00.1 {did:10fb vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:7b11} `-[00]-+-02.2----[30] {did:3c06 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 4 - ACTIVE - (x4 @ 8.0GT/s) `-[30]---00.0 {did:2031 vid:1077 (QLogic Corp.) rid:02 cc:0c0400 svid:1077 (QLogic Corp.) sid:024d} `-[30]---00.1 {did:2031 vid:1077 (QLogic Corp.) rid:02 cc:0c0400 svid:1077 (QLogic Corp.) sid:024d} `-[00]-+-03.0----[40] {did:3c08 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 2 - ACTIVE - (x8 @ 8.0GT/s) `-[40]---00.0 {did:8018 vid:11f8 (PMC-Sierra Inc.) rid:06 cc:010700 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} `-[00]-+-03.2----[50] {did:3c0a vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 5 - ACTIVE - (x4 @ 8.0GT/s) `-[50]---00.0 {did:8030 vid:1077 (QLogic Corp.) rid:02 cc:020000 svid:1077 (QLogic Corp.) sid:024e} `-[50]---00.1 {did:8030 vid:1077 (QLogic Corp.) rid:02 cc:020000 svid:1077 (QLogic Corp.) sid:024e} `-[50]---00.2 {did:8031 vid:1077 (QLogic Corp.) rid:02 cc:0c0400 svid:1077 (QLogic Corp.) sid:024f} `-[50]---00.3 {did:8031 vid:1077 (QLogic Corp.) rid:02 cc:0c0400 svid:1077 (QLogic Corp.) sid:024f} `-[50]---00.4 {did:8032 vid:1077 (QLogic Corp.) rid:02 cc:028000 svid:1077 (QLogic Corp.) sid:0250} `-[50]---00.5 {did:8032 vid:1077 (QLogic Corp.) rid:02 cc:028000 svid:1077 (QLogic Corp.) sid:0250} SKT[1]_ `-[80]-+-01.0----[88] {did:3c02 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : NET 0/1 - ACTIVE - (x8 @ 5.0GT/s) `-[88]---00.0 {did:1528 vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:484f} `-[88]---00.1 {did:1528 vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:484f} `-[80]-+-02.2----[98] {did:3c06 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : NET 2/3 - ACTIVE - (x8 @ 5.0GT/s) `-[98]---00.0 {did:1528 vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:484f} `-[98]---00.1 {did:1528 vid:8086 (Intel Corporation) rid:01 cc:020000 svid:108e (Oracle/SUN) sid:484f} `-[80]-+-03.0----[a0] {did:3c08 vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 3 - ACTIVE - (x8 @ 8.0GT/s) `-[a0]---00.0 {did:8018 vid:11f8 (PMC-Sierra Inc.) rid:06 cc:010700 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} `-[80]-+-03.2----[b0] {did:3c0a vid:8086 (Intel Corporation) rid:07 cc:060400 svid:108e (Oracle/SUN) sid:484F} : PCIe 6 - ACTIVE - (x8 @ 8.0GT/s) `-[b0]---00.0 {did:8018 vid:11f8 (PMC-Sierra Inc.) rid:06 cc:010700 svid:0000 (Gammagraphx, Inc. (or missing ID)) sid:0000} [(restricted_shell) ORACLESP-1315FM2008:~]#
The command "show -display properties -level all -format nowrap /System/ will display all the properties of the various components (targets) seen by the ILOM. The -level all option makes it recursive and thus will display anything beneath. So if one starts with "System", everything will be displayed. Output can be constrained by using one of System's targets (ex: /System/Memory). -> show -display properties -level all -format nowrap /System/
/System Properties: health = OK health_details = - open_problems_count = 0 type = Rack Mount model = FS1 Controller qpart_id = urn:uuid:e468198c-c760-11e0-a863-080020a9ed93 part_number = 70893370 serial_number = 1315FM2008 system_identifier = (none) system_fw_version = 3.2.6.32 primary_operating_system = Not Available primary_operating_system_detail = Comprehensive System monitoring is not available. Ensure the host is running with the Hardware Management Pack. For details go to http://www.oracle.com/goto/ilom-redirect/hmp-osa host_primary_mac_address = 00:21:28:a1:c6:40 ilom_address = 169.254.2.9 ilom_mac_address = 00:21:28:A1:C6:44 locator_indicator = Off power_state = On actual_power_consumption = 300 watts action = (none) /System/Processors Properties: health = OK health_details = - architecture = x86 64-bit summary_description = Two Intel Xeon Processor E5 Series installed_cpus = 2 max_cpus = 2 /System/Processors/CPUs Properties: /System/Processors/CPUs/CPU_0 Properties: health = OK health_details = - part_number = 060D serial_number = Not Available location = P0 (CPU 0) model = Intel(R) Xeon(R) CPU E5-2620 0 @ 2.00GHz max_clock_speed = 2.000 GHz total_cores = 6 enabled_cores = 6 temperature = Not Supported /System/Processors/CPUs/CPU_1 Properties: health = OK health_details = - part_number = 060D serial_number = Not Available location = P1 (CPU 1) model = Intel(R) Xeon(R) CPU E5-2620 0 @ 2.00GHz max_clock_speed = 2.000 GHz total_cores = 6 enabled_cores = 6 temperature = Not Supported /System/Memory Properties: health = OK health_details = - installed_memory = 208 GB installed_dimms = 16 max_dimms = 16 /System/Memory/DIMMs Properties: /System/Memory/DIMMs/DIMM_0 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFE726 location = P0/D0 (CPU 0 DIMM 0) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_1 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFF5BE location = P0/D1 (CPU 0 DIMM 1) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_2 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFE76C location = P0/D2 (CPU 0 DIMM 2) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_3 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFF76F location = P0/D3 (CPU 0 DIMM 3) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_4 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFF590 location = P0/D4 (CPU 0 DIMM 4) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_5 Properties: health = OK health_details = - part_number = 001-0003-01,HMT42GR7MFR4A-PB serial_number = 00AD0113023DC8FF37 location = P0/D5 (CPU 0 DIMM 5) manufacturer = Hynix Semiconductor Inc. memory_size = 16 GB /System/Memory/DIMMs/DIMM_6 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFE76B location = P0/D6 (CPU 0 DIMM 6) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_7 Properties: health = OK health_details = - part_number = 001-0003-01,HMT42GR7MFR4A-PB serial_number = 00AD0113023D48FF20 location = P0/D7 (CPU 0 DIMM 7) manufacturer = Hynix Semiconductor Inc. memory_size = 16 GB /System/Memory/DIMMs/DIMM_8 Properties: health = OK health_details = - part_number = 001-0003-01,VRA7EA4B5D08S7 serial_number = 01400114510C3DE58B location = P1/D0 (CPU 1 DIMM 0) manufacturer = Viking Components memory_size = 4 GB /System/Memory/DIMMs/DIMM_9 Properties: health = OK health_details = - part_number = 001-0003-01,VRA7EA4B5D08S7 serial_number = 01400115130C3DE583 location = P1/D1 (CPU 1 DIMM 1) manufacturer = Viking Components memory_size = 4 GB /System/Memory/DIMMs/DIMM_10 Properties: health = OK health_details = - part_number = 001-0003-01,VRA7EA4B5D08S6 serial_number = 01400114060C364B2B location = P1/D2 (CPU 1 DIMM 2) manufacturer = Viking Components memory_size = 4 GB /System/Memory/DIMMs/DIMM_11 Properties: health = OK health_details = - part_number = 001-0003-01,VRA7EA4B5D08S6 serial_number = 01400114060C364CB1 location = P1/D3 (CPU 1 DIMM 3) manufacturer = Viking Components memory_size = 4 GB /System/Memory/DIMMs/DIMM_12 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014B00A8D location = P1/D4 (CPU 1 DIMM 4) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_13 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014B01842 location = P1/D5 (CPU 1 DIMM 5) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_14 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014AFE769 location = P1/D6 (CPU 1 DIMM 6) manufacturer = Samsung memory_size = 16 GB /System/Memory/DIMMs/DIMM_15 Properties: health = OK health_details = - part_number = 001-0003-01,M393B2G70BH0-YK0 serial_number = 00CE03135014B00F79 location = P1/D7 (CPU 1 DIMM 7) manufacturer = Samsung memory_size = 16 GB /System/Power Properties: health = OK health_details = - actual_power_consumption = 306 watts max_permitted_power = 647 watts installed_power_supplies = 2 max_power_supplies = 2 /System/Power/Power_Supplies Properties: /System/Power/Power_Supplies/Power_Supply_0 Properties: health = OK health_details = - part_number = 7050671-01 serial_number = C90199 manufacturer = Delta Electronics location = PS0 (Power Supply 0) input_power = Present output_power = 114 watts /System/Power/Power_Supplies/Power_Supply_1 Properties: health = OK health_details = - part_number = 7050671-01 serial_number = C90410 manufacturer = Delta Electronics location = PS1 (Power Supply 1) input_power = Present output_power = 115 watts /System/Cooling Properties: health = OK health_details = - installed_chassis_fans = 10 max_chassis_fans = 10 installed_power_supply_fans = Not Supported max_power_supply_fans = Not Supported inlet_temp = 29 degrees C exhaust_temp = 37 degrees C /System/Cooling/Fans Properties: /System/Cooling/Fans/Fan_0 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM0 (Fan Module 0) fan_percentage = 38 % /System/Cooling/Fans/Fan_1 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM0 (Fan Module 0) fan_percentage = 38 % /System/Cooling/Fans/Fan_2 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM1 (Fan Module 1) fan_percentage = 38 % /System/Cooling/Fans/Fan_3 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM1 (Fan Module 1) fan_percentage = 38 % /System/Cooling/Fans/Fan_4 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM2 (Fan Module 2) fan_percentage = 37 % /System/Cooling/Fans/Fan_5 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM2 (Fan Module 2) fan_percentage = 38 % /System/Cooling/Fans/Fan_6 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM3 (Fan Module 3) fan_percentage = 38 % /System/Cooling/Fans/Fan_7 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM3 (Fan Module 3) fan_percentage = 37 % /System/Cooling/Fans/Fan_8 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM4 (Fan Module 4) fan_percentage = 38 % /System/Cooling/Fans/Fan_9 Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM4 (Fan Module 4) fan_percentage = 38 % /System/Storage Properties: health = Not Available health_details = Comprehensive System monitoring is not available. Ensure the host is running with the Hardware Management Pack. For details go to http://www.oracle.com/goto/ilom-redirect/hmp-osa installed_disks = 0 max_disks = 4 installed_disk_size = Not Available add_on_disks = Not Available add_on_disk_size = Not Available logical_volumes = Not Available disk_controllers = Not Available /System/Networking Properties: health = OK health_details = - installed_eth_nics = 4 installed_infiniband_hcas = 0 /System/Networking/Ethernet_NICs Properties: /System/Networking/Ethernet_NICs/Ethernet_NIC_0 Properties: health = OK health_details = - location = NET0 (Ethernet NIC 0) manufacturer = INTEL part_number = X540 serial_number = Not Available mac_addresses = 00:21:28:a1:c6:40 /System/Networking/Ethernet_NICs/Ethernet_NIC_1 Properties: health = OK health_details = - location = NET1 (Ethernet NIC 1) manufacturer = INTEL part_number = X540 serial_number = Not Available mac_addresses = 00:21:28:a1:c6:41 /System/Networking/Ethernet_NICs/Ethernet_NIC_2 Properties: health = OK health_details = - location = NET2 (Ethernet NIC 2) manufacturer = INTEL part_number = X540 serial_number = Not Available mac_addresses = 00:21:28:a1:c6:42 /System/Networking/Ethernet_NICs/Ethernet_NIC_3 Properties: health = OK health_details = - location = NET3 (Ethernet NIC 3) manufacturer = INTEL part_number = X540 serial_number = Not Available mac_addresses = 00:21:28:a1:c6:43 /System/PCI_Devices Properties: installed_add_ons = 6 add_on_start_slot = 1 max_add_ons = 6 /System/PCI_Devices/On-board Properties: /System/PCI_Devices/On-board/Device_0 Properties: description = NET0 Intel X540 Gigabit Ethernet Controller location = Not Supported /System/PCI_Devices/On-board/Device_1 Properties: description = NET1 Intel X540 Gigabit Ethernet Controller location = Not Supported /System/PCI_Devices/On-board/Device_2 Properties: description = NET2 Intel X540 Gigabit Ethernet Controller location = Not Supported /System/PCI_Devices/On-board/Device_3 Properties: description = NET3 Intel X540 Gigabit Ethernet Controller location = Not Supported /System/PCI_Devices/Add-on Properties: /System/PCI_Devices/Add-on/Device_1 Properties: part_number = X1109A-Z description = Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter location = PCIE1 (PCIe Slot 1) pci_vendor_id = 0x8086 pci_device_id = 0x10fb pci_subvendor_id = 0x108e pci_subdevice_id = 0x7b11 /System/PCI_Devices/Add-on/Device_2 Properties: part_number = 7101674 description = Sun Storage 16 Gb Fibre Channel PCIe Universal FC HBA, Qlogic location = PCIE4 (PCIe Slot 4) pci_vendor_id = 0x1077 pci_device_id = 0x2031 pci_subvendor_id = 0x1077 pci_subdevice_id = 0x024d /System/PCI_Devices/Add-on/Device_3 Properties: part_number = Not Recognized description = Not Recognized location = PCIE2 (PCIe Slot 2) pci_vendor_id = 0x11f8 pci_device_id = 0x8018 pci_subvendor_id = 0x0000 pci_subdevice_id = 0x0000 /System/PCI_Devices/Add-on/Device_4 Properties: part_number = 7101674 description = Sun Storage 16 Gb Fibre Channel PCIe Universal NIC HBA, Qlogic location = PCIE5 (PCIe Slot 5) pci_vendor_id = 0x1077 pci_device_id = 0x8030 pci_subvendor_id = 0x1077 pci_subdevice_id = 0x024e /System/PCI_Devices/Add-on/Device_5 Properties: part_number = Not Recognized description = Not Recognized location = PCIE3 (PCIe Slot 3) pci_vendor_id = 0x11f8 pci_device_id = 0x8018 pci_subvendor_id = 0x0000 pci_subdevice_id = 0x0000 /System/PCI_Devices/Add-on/Device_6 Properties: part_number = Not Recognized description = Not Recognized location = PCIE6 (PCIe Slot 6) pci_vendor_id = 0x11f8 pci_device_id = 0x8018 pci_subvendor_id = 0x0000 pci_subdevice_id = 0x0000 /System/Firmware Properties: system_fw_version = 3.2.6.32 /System/Firmware/Other_Firmware Properties: /System/Firmware/Other_Firmware/Firmware_0 Properties: component = ILOM type = ILOM Firmware version = 3.2.6.32 /System/Firmware/Other_Firmware/Firmware_1 Properties: component = BIOS type = System BIOS version = 21000227 /System/BIOS Properties: system_bios_version = 21000227 boot_mode = Legacy reset_to_defaults = none /System/BIOS/Config Properties: config_sync_status = Ok restore_status = Ok restore_options = all load_uri = (none) dump_uri = (none) action = (none) /System/Log Properties: clear = (none) ->
Attachments This solution has no attachment |
||||||||||||||
|