Applies to:Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.3 to SDM 9.3 [Release SDM 9.0]Tekelec GoalThe goal of this document is to provide a procedure on how to shift Geo Redundancy state of sites from Reference Protected to Replica and vice versa. Source: http://docs.oracle.com/en/industries/communications/subscriber-data-management/index.html
SolutionPrerequisites
* netstat –anp | grep 8080 |wc -l For SOAP request * netstat –anp | grep 8787 |wc -l For REST request 2. Check all the Active alarms and make sure they are accounted for before starting this activity.
Steps
Redundancy Enabled = Disabled DbGeoState = UnassignedDisabled At the same time, Replica site's status becomes:- Redundancy Enabled = Enabled DbGeoState = PendingReference 4. In Replica site, click on "Force Geo Redundancy" and its Status becomes :- Redundancy Enabled = Enabled DbGeoState = Reference At the same time, Reference Protected site's status becomes:- Redundancy Enabled = Disabled DbGeoState = UnassignedDisabled 5. In Reference Protected Site, Click on "Enable Geo Redundancy" and its Status becomes :- Redundancy Enabled = Enabled DbGeoState = UnassignedEnabled 6. In Reference Protected Site, Click on "Resume Geo Redundancy" and its Status becomes :- Redundancy Enabled = Enabled DbGeoState = Negotiating At the same time, Replica site's status becomes:- Redundancy Enabled = Enabled DbGeoState = Reference 7. Wait for few minutes and refresh the GUI. Now Status on Reference Protected site becomes :- Redundancy Enabled = Enabled DbGeoState = Replica At the same time, Replica site's status becomes:- Redundancy Enabled = Enabled DbGeoState = Reference Protected
This completes the shifting of Geo Redundancy state from Reference Protected to Replica and vice versa from one site to another.
Post Activity:- 1. Make sure there are no alarms present in both sites related to Geo Redundancy/Replication. 2. Once this procedure is complete, you can ask customer to start Provisioning to newly promoted Reference Protected site.