Asset ID: |
1-71-2262478.1 |
Update Date: | 2017-05-09 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2262478.1
:
Receive and Transmit Values in DSR Measurement Report Diameter Ingress Transaction Performance Are Not Equal
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-14784786921>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.3.0 and later
Information in this document applies to any platform.
Goal
Why it could happen that the sum of TxAnswer* values for all connections for a measurement period (5 minutes) is not always equal to the sum of RxConnRequestMessages values for all connections for a measurement period (5 minutes) ?
The ratio between the both elements is always close to 1
Solution
It can never be confirmed that all messages received during a five minutes period will be sent as well during the same five minutes period.
- At low loads the issue is magnified : for instance 1 message less or more out of total 10 will have a 10% impact on result
- At high loads ratio become closer to 1 : the messages processed at start/end of period will be very less compared to the volume processed during the period
Attachments
This solution has no attachment