Asset ID: |
1-71-2259513.1 |
Update Date: | 2017-04-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2259513.1
:
Diameter Signaling Router - Set Ring Buffer Sizes Failed On DL380Gen9
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-14760389911>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.2.0 and later
Tekelec
Goal
In doc:
http://docs.oracle.com/cd/E68457_01/docs.72/E64707_rev_02.pdf
Performed the procedure 5 but errors message appeared as below by applying the commands on eth01, eth02, eth05 and eth06.
(Bond0 = eth01,eth02 / Bond1 = eth05,eth06).
[root@hostname upgrade]# netAdm set --device=eth05 --ringBufferRx=4096 --ringBufferTx=4096
ERROR: Desired ringBufferRx: 4096 Actual: 200
ERROR: Specified ethtool_opts could not be set!
ERROR: Failed to bring eth05 back up
ERROR: Failed to restart eth05
Interface eth05 updated
Solution
Ehternet cards being used are not the intended ones
Lets revisit the document
http://docs.oracle.com/cd/E68457_01/docs.72/E64707_rev_02.pdf
Procedure 5, Step 8 Says:
The following commands will increase the ring buffer sizes on...HP DL380 Gen 9 Ethernet Interfaces:
Note: Refer to Section 3.4 for network interface server reference table
Now looking at Section 3.4
Note:
For HP DL380 Gen 9 servers
two 2pt 10 Gigabit PCI cards are required while running the segregated signaling network topology
otherwise one 2pt 10 Gigabit PCI card is required
For HP DL380 (with 2pt 10 Gigabit in PCI Slots 1 and 3) (Gen 9)
Following network interfaces have been mentioned:
<ethernet_interface_1> eth11 (ethernet slot 1, port 1)
<ethernet_interface_2> eth12 (ethernet slot 1, port 2)
<ethernet_interface_3> eth31 (ethernet slot 3, port 1)
<ethernet_interface_4> eth32 (ethernet slot 3, port 2)
From available information the HPGen9 built in 1Gb ethernet cards are used while document is expecting 2 port 10 Gigabit Cards.
Check if the server has 10 Gb PCI card available as required in section 3.4 (and mentioned above)
Refer to following document about HP DL380 Gen9 Servers
Oracle Communications Diameter Signaling Router Release 7.4 Planning Guide >> Page 51 >> Table 43: HP Gen9 Configuration Options
Attachments
This solution has no attachment