Solution Type  Technical Instruction Sure

Solution  2246881.1 :   Alarms Post-Upgrade: Alarm ID 13071 (No Northbound Provisioning Connections)  


Related Items
  • Oracle Communications User Data Repository
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec UDR
  •  




In this Document
Goal
Solution


Created from <SR 3-14521708403>

Applies to:

Oracle Communications User Data Repository - Version UDR 12.1 and later
Information in this document applies to any platform.

Goal

To assist the user of the OCUDR platform to resolve this alarm whenever it is seen.

 

Solution

Provisioning interface is enabled and no remote provisioning clients are connected.

 

Recovery:

1. Check that the provisioning system is attempting to establish a SOAP or REST connection, and verify the TCP/IP connectivity between the provisioning system and UDR.

2. View the whitelist from the Provisioning Connections GUI option on the UDR Configuration menu.

  • Ensure that the IP address of the provisioning system has been added to the IP whitelist of allowed provisioning clients.

 

Once provisioning is initiated, from either a REST or SOAP connection, the Alarm will clear.

 

 