Solution Type Technical Instruction Sure Solution 2246881.1 : Alarms Post-Upgrade: Alarm ID 13071 (No Northbound Provisioning Connections)
In this Document
Created from <SR 3-14521708403> Applies to:Oracle Communications User Data Repository - Version UDR 12.1 and laterInformation in this document applies to any platform. GoalTo assist the user of the OCUDR platform to resolve this alarm whenever it is seen.
SolutionProvisioning interface is enabled and no remote provisioning clients are connected.
Recovery: 1. Check that the provisioning system is attempting to establish a SOAP or REST connection, and verify the TCP/IP connectivity between the provisioning system and UDR. 2. View the whitelist from the Provisioning Connections GUI option on the UDR Configuration menu.
Once provisioning is initiated, from either a REST or SOAP connection, the Alarm will clear.