Solution Type  Technical Instruction Sure

Solution  2244756.1 :   SL3000 - How To Determine If There Is Power To The Op Panel  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: added new KB
Created from <SR 3-14309563181>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 How to determine if the SL3000 library has power to the Operators Panel

Solution

 1. Open the back door to the SL3000 Base Module.

 2. Loosen the 2 green thumbscrews to remove the Electronics Module Cover Plate.

 3. Tilt the cover plate at the top and lift out of the tray.

 4. You should now be able to see the SL3000 PUN LED's.

 5. Verify that LED 14 ( CR2304 ) is lit.  See picture below.

 PUN LED's

 6. Replace the op panel if the led is lit and the op panel does not power up.

 7. Replace the PUN if the LED is not lit as no +48V is present.

 