Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2237140.1
Update Date:2018-04-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  2237140.1 :   IBM LTO7 - How to Remove/Replace an IBM 1U Rackmount T ape Enclosure  


Related Items
  • IBM LTO7 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU

Applies to:

IBM LTO7 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Goal

 IBM LTO7 - How to Remove/Replace an IBM 1U Rackmount Tape Enclosure

Solution

 DISPATCH INSTRUCTIONS
- WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 90 minutes
- TASK COMPLEXITY: 1
REMOVAL/REPLACEMENT INSTRUCTIONS:
- PROBLEM OVERVIEW: The 1U Rackmount Tape Enclosure has been determined to be defective.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

Refer to the Oracle StorageTek 1U Rackmount Tape Enclosure Setup, Operator, and Service Guide, PN E58300-01, Chapter 7 for pictures and figures.

Use the following procedure to prepare the 1U Rackmount Tape Enclosure for removal or installation of a storage device or other component.
Note: Before performing this procedure, ensure that there is no activity between the host system and the installed devices or operations being performed by the installed devices. Turning of f the 1U Rackmount Tape Enclosure power during activity could result in loss of data.
1. Remove any media from the installed devices.
Note: Device means either drive or bay blank.
2. Turn off the power to the 1U Rackmount Tape Enclosure.
3. Remove the 1U Rackmount Tape Enclosure from the host system configuration. (For instructions, refer to your system manuals.)
4. Unplug the 1U Rackmount Tape Enclosure power cable from the electrical outlet. The 1U Rackmount Tape Enclosure is now prepared for removal or installation.

- WHAT ACTIONS ARE REQUIRED?:

Replacing an Enclosure:
1. Prepare the 1U Rackmount Tape Enclosure for Service. See“Preparing the 1URackmount Tape Enclosure for Removal or Installation of a Storage Device orOther Component” on page 76for the correct procedure.
2. Remove the 1U Rackmount Tape Enclosure from the rack (see“Removing the1U Rackmount Tape Enclosure from a Rack” on page 14) and place it on an ESD protected work surface.
3. Remove the new Enclosure FRU from its packaging and install it onto theslide rails. Pull the slide rails forward 1 until they click, twice, into place.  Carefully lift the Enclosure FRU and tilt it into position over the slide rails sothat the rear posts 2 on the Enclosure FRU line up with the rear slots 3 on the slide rails. Slide the server down until the rear posts slip into the two rear slots, and then slowly lower the front of the Enclosure FRU 4 until the other posts slip into the other slots on the slide rails. Make sure that the front latch 5 slides over the posts.

Figure 46. Install Enclosure FRU on Slide Rails

4. Note the location of the devices in the old 1U Rackmount Tape Enclosure.  Remove the Half High Bay Blanks from those locations in the Enclosure FRU.
To remove the Half High Bay Blank, push the drive latch 1 toward the Half High Bay Blank and begin to pull the blank out of the enclosure. Grasp the Bay Blank 2 and pull it out of the enclosure.

Figure 47. Remove Half-High Bay Blanks

5. Remove the Tape Drives from the 1U Rackmount Tape Enclosure. To removethe devices, push the drive latch 1 toward the drive assembly and begin to pull the drive out of the enclosure. Grasp the drive 2 and pull the assembly out of the drive bay. Disconnect the cables 3 from the drive assembly.

Figure 48. Removing a Drive Assembly

6. Install each device into the Enclosure FRU into its noted location. To install the drive assemblies, attach the Drive Latch 1 to the drive assembly 2 and insert both into the drive bay until they click into place.

Figure 49. Inserting a Drive

7. To remove the Top Cover of the Enclosure FRU, loosen the Top Cover Thumb Screws 1.

Figure 50. Top Cover Thumb Screws

8. Slide the Enclosure FRU Top Cover toward the rear of the enclosure 1 and lift to remove 2.

Figure 51. Top Cover

9. Note the location of each Interface assembly in the 1U Rackmount Tape Enclosure. To remove each Interface assembly from the 1U Rackmount Tape Enclosure, remove the Interface Assembly from the drive connector 1 and remove the power connector 2.

Figure 52. Remove Interface Assembly

10. Note the locations of the Blank Back Plates to be removed from the newEnclosure FRU. To remove a Blank Back Plate, pull the back plate pin 1 to release the Blank Back Plate, and remove the Blank Back Plate 2 from the rear panel slot.

Figure 53. Remove Blank Back Plate

11. Install each Interface Assembly into the Enclosure FRU. Attach the Interface Assembly to the drive connector 1, and attach the Power Connector 2.

Figure 54.Attach Interface Assembly

12. To Insert the Interface Assembly into the rear panel slot, insert the tab on the back plate into the indent in the back panel opening 1, pull the pin on the back plate 2 and push the back plate into the back panel opening 3 until it clicks into place.

Figure 55. Insert Interface Assembly Back Plate

13. Complete the 1U Rackmount Tape Enclosure Service Procedure. See“Completing the 1U Rackmount Tape Enclosure Service Procedure” on page 89 for the correct procedure.

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

1. Plug the 1U Rackmount Tape Enclosure power cable into the electrical outlet.

2. Add the 1U Rackmount Tape Enclosure to the host system configuration

3. Turn on the power to the 1U Rackmount  Tape Enclosure.

PARTS NOTE: N/A

REFERENCE INFORMATION: StorageTek 1U Rackmount Tape Enclosure Setup, Operator, and Service Guide, PN E58300-01