![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2237140.1 : IBM LTO7 - How to Remove/Replace an IBM 1U Rackmount T ape Enclosure
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:IBM LTO7 Tape Drive - Version All Versions and laterInformation in this document applies to any platform. GoalIBM LTO7 - How to Remove/Replace an IBM 1U Rackmount Tape Enclosure Solution DISPATCH INSTRUCTIONS Refer to the Oracle StorageTek 1U Rackmount Tape Enclosure Setup, Operator, and Service Guide, PN E58300-01, Chapter 7 for pictures and figures. Use the following procedure to prepare the 1U Rackmount Tape Enclosure for removal or installation of a storage device or other component. - WHAT ACTIONS ARE REQUIRED?: Replacing an Enclosure: Figure 46. Install Enclosure FRU on Slide Rails 4. Note the location of the devices in the old 1U Rackmount Tape Enclosure. Remove the Half High Bay Blanks from those locations in the Enclosure FRU. Figure 47. Remove Half-High Bay Blanks 5. Remove the Tape Drives from the 1U Rackmount Tape Enclosure. To removethe devices, push the drive latch 1 toward the drive assembly and begin to pull the drive out of the enclosure. Grasp the drive 2 and pull the assembly out of the drive bay. Disconnect the cables 3 from the drive assembly. Figure 48. Removing a Drive Assembly 6. Install each device into the Enclosure FRU into its noted location. To install the drive assemblies, attach the Drive Latch 1 to the drive assembly 2 and insert both into the drive bay until they click into place. Figure 49. Inserting a Drive 7. To remove the Top Cover of the Enclosure FRU, loosen the Top Cover Thumb Screws 1. Figure 50. Top Cover Thumb Screws 8. Slide the Enclosure FRU Top Cover toward the rear of the enclosure 1 and lift to remove 2. Figure 51. Top Cover 9. Note the location of each Interface assembly in the 1U Rackmount Tape Enclosure. To remove each Interface assembly from the 1U Rackmount Tape Enclosure, remove the Interface Assembly from the drive connector 1 and remove the power connector 2. Figure 52. Remove Interface Assembly 10. Note the locations of the Blank Back Plates to be removed from the newEnclosure FRU. To remove a Blank Back Plate, pull the back plate pin 1 to release the Blank Back Plate, and remove the Blank Back Plate 2 from the rear panel slot. Figure 53. Remove Blank Back Plate 11. Install each Interface Assembly into the Enclosure FRU. Attach the Interface Assembly to the drive connector 1, and attach the Power Connector 2. Figure 54.Attach Interface Assembly 12. To Insert the Interface Assembly into the rear panel slot, insert the tab on the back plate into the indent in the back panel opening 1, pull the pin on the back plate 2 and push the back plate into the back panel opening 3 until it clicks into place. Figure 55. Insert Interface Assembly Back Plate 13. Complete the 1U Rackmount Tape Enclosure Service Procedure. See“Completing the 1U Rackmount Tape Enclosure Service Procedure” on page 89 for the correct procedure. WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: 1. Plug the 1U Rackmount Tape Enclosure power cable into the electrical outlet. 2. Add the 1U Rackmount Tape Enclosure to the host system configuration 3. Turn on the power to the 1U Rackmount Tape Enclosure. PARTS NOTE: N/A REFERENCE INFORMATION: StorageTek 1U Rackmount Tape Enclosure Setup, Operator, and Service Guide, PN E58300-01 Attachments This solution has no attachment |
||||||||||||||
|