Solution Type  Technical Instruction Sure

Solution  2235975.1 :   Diameter Signaling Router (DSR) - Why System Raises Backup Failure Alarm (10020) From NOAM and SOAM Servers Every Day Around 2:15am?  


Related Items
  • BNS Platform Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution


Created from <SR 3-14276998161>

Applies to:

BNS Platform Hardware - Version DSR 4.0 and later
Information in this document applies to any platform.

Goal

Why system is raising a Backup Failure alarm (10020) from NOAM and SOAM servers every day around 2:15am?
 

Solution

The backup code will issue this alarm "clear" if a backup successfully occurs. The "clear" is raised for the active NO and SO for the 2:15 configuration backup (daily night backup). This "clear" alarm can be considered as a notification about the backup success.
To summarize, this is the expected behavior of the system after the nightly backup is done.