Solution Type Technical Instruction Sure Solution 2230641.1 : Egress Throttling Group (ETG) Fails To Activate
In this Document
Created from <SR 3-13438589751> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.1.0 to DSR 7.1.2 [Release DSR 7.0]Information in this document applies to any platform. GoalResolve ETG Throttling Failing to Activate. SolutionWhen this bug# 25392005 condition exists, it can be confirmed on the MP with the issue by doing the following: # pegstat -W -mSms*Update*
For MP that has issue with aggregation, will not have any measurement being pegged. e.g. <<<<<=== loop=6 01/13/2017 16:43:04.827 deltaT=12.041 ===>>>>>
SmsTxUpdateReq[2]: ..............0 0.00 /s SmsRxUpdateResp[2]: ..............0 0.00 /s If the issue exists contact Oracle support. Workaround:
References<BUG:25392005> - ETG THROTTLING FAILS TO ACTIVATEAttachments This solution has no attachment |
||||||||||||||||
|