Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2230641.1
Update Date:2017-02-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  2230641.1 :   Egress Throttling Group (ETG) Fails To Activate  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution
References


Created from <SR 3-13438589751>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.1.0 to DSR 7.1.2 [Release DSR 7.0]
Information in this document applies to any platform.

Goal

Resolve ETG Throttling Failing to Activate. 

Solution

When this bug# 25392005 condition exists, it can be confirmed on the MP with the issue by doing the following:

# pegstat -W -mSms*Update*

For MP that has issue with aggregation, will not have any measurement being pegged. e.g.

  <<<<<=== loop=6 01/13/2017 16:43:04.827 deltaT=12.041 ===>>>>>
  SmsTxUpdateReq[2]: ..............0 0.00 /s
  SmsRxUpdateResp[2]: ..............0 0.00 /s

If the issue exists contact Oracle support.

Workaround:

  1. Verify which MP is the Active DA_MP_Leader (this can be done on all MP's to verify their status)
    # ha.mystate | grep DA_MP_Leader
      DA_MP_Leader Active C1317.125 0 0112:105048.437
  2. From active MP do:
    # ha.push -r DA_MP_Leader -t 10
  3. Confirm using step 1 command that there is a new Active DA_MP_leader

 

References

<BUG:25392005> - ETG THROTTLING FAILS TO ACTIVATE

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback