Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2230567.1
Update Date:2017-05-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  2230567.1 :   Space Used In "/var" Exceeds the Set Limit 90%. 100% Used.  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Goal
Solution


Created from <SR 3-14056370931>

Applies to:

Oracle Communications EAGLE (Software) - Version EPAP 16.1 and later
Information in this document applies to any platform.

Goal

/var exceeds 90%

Solution

/var/log/messages is filled with martian error. eth04 was connected to Switch A port 5 and 6.
After removing the cable, the martian error stopped coming and /var partition no more filling rapidly. 

eth04 connection to Switch-A port 5 and 6 is needed when one wants to configure Backup sync network (or sync redundancy as we call it) or backup provisioning network.

 