Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2228341.1
Update Date:2018-04-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  2228341.1 :   SL8500 - Bulk CAP Command REQUIRED During Installation  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidentual for service personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

Bulk CAP Command REQUIRED during install

Solution

When installing a BULK CAP on either a new SL8500 or as an upgrade, you must enter the command "config check" and reboot the controller, BEFORE allowing the robotics to boot.

Make sure this is done before closing the doors. Reboot the controller with the doors open.

This instruction is in the upgrade Conversion Bill and the SL8500 Installation Manual for Bulk CAP Libraries document.