Goal

How to Clear ECC Correctable Memory Error On DSR servers.

Solution

If a reseat was not done please do so as the next step. This has been shown to clear ECC correctable Memory Error on c-Class blades:

  • To reseat the blade you can do it locally (i.e., physically remove the blade from the enclosure and reinsert)
    Or
  • Remotely via the OA:
    1. Login to OA
    2. Run "show server names"
    3. Note the bay number in the previous output for the server in question.
    4. Run "reset server "
      This causes all power to be momentarily removed from the server.
      Then the server will boot back up.

 