Solution Type Technical Instruction Sure Solution 2211373.1 : Private Cloud Appliance (PCA): Support Strategy for Replacing a ZFS Logzilla with a Higher Capacity SSD
In this Document
Applies to:Oracle Virtual Compute Appliance X3-2 Hardware - Version All Versions and laterPrivate Cloud Appliance - Version 2.1.1 and later Private Cloud Appliance X5-2 Hardware - Version All Versions and later Private Cloud Appliance X6-2 Server Upgrade - Version All Versions and later Oracle Virtual Compute Appliance X4-2 Hardware - Version All Versions and later Information in this document applies to any platform. GoalThis document provides support strategy information for replacing Private Cloud Appliance (PCA) ZFS Appliance Logzilla with Higher Capacity SSD. Due to very limited availability of some older model Logzilla SSDs, a Logzilla with a Higher Capacity (200GB) may be provided to replace a lower capacity device. Updating your PCA software to the recommended release will help to expedite part replacements. IMPORTANT NOTE:
If you are unable to upgrade to the recommended release, the replacement parts request (for a lower capacity device) will go on backorder with no known time of fulfillment. SolutionFor all versions of Private Cloud Appliance (PCA) and Oracle Virtual Cloud Appliance (OVCA) the minimum mandatory release is patch 22185511: Private Cloud Appliance release 2.1.1. Below is the snippet from the Release 2.1.1 Administrators guide If your Oracle PCA is currently running Controller Software Release 2.0.5, you can upgrade to Release 2.1.1. - new network customization and monitoring functionality
We never had 18gb drives in PCA so with PCA X-3 we were already at the minimum level to use 73gb drives. For PCA X-4 and X-5 we used ZS3-ES which released with PCA X-4 with image 1.1.1 and had zfs 2013.1.0.1 For the 200gb drives that might replace the 73gb drives we need to be at a minimum zfs 2013.1.4.1 So the bottom line here is that to cover PCA for this drive size issue the recommendation would be to insure the PCA image is no older that 2.1.1, which fixes many other issues and no one should be running anything older
References<NOTE:2166733.1> - Sun Storage 7310/7410 Storage Systems running ZFS Storage Appliance (ZFSSA) Software Version 2011.1.9.3 or earlier with 100GB Readzilla SATA Disk Drives Require ZFSSA Upgrade to Avoid Drive Compatibility/Availability Issues<NOTE:1984011.1> - Oracle ZFS Storage Appliance: Support Strategy for Replacing a ZFS Logzilla with a Higher Capacity SSD Attachments This solution has no attachment |
||||||||||||||||
|