Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2208127.1
Update Date:2016-11-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  2208127.1 :   For Diameter Signaling Router (DSR) SS7 Inter-Working Function (IWF), Can the SCCP Address Indicator For ITU-N destination be set to 0 (International)?  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution


Created from <SR 3-13459783521>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 6.0 and later
Information in this document applies to any platform.

Goal

Can the SCCP Address Indicator for ITU-N (ITU-National) connections be set to '0' (International) in the MD-IWF configuration?

Solution

No, there is no capability provided to change the CxPA Address Indicator value in the DSR MD-IWF configuration.

The DSR sets the value according to destination network type. If ITU-N or ANSI, the CxPA Address Indicator will be set to 1, and if ITU-I it will be set to 0.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.